WE866E4-P AT Commands Reference Guide
80572ST10887A Rev. 0.0
134
2018-02-16
PRELIMINAR
Y
Response
, describes the responses and remarks for FWUP HTTP Client
command.
Synchronous Response
, describes the synchronous responses and remarks for FWUP HTTP
Client command.
Table 291 FWUP HTTP Client Parameters
Parameters Mandatory/Optional
Value
Description
Server
Address
Mandatory
Value range:
1-63
Format:
String
Default value:
N/A
It specifies the HTTP server address or the
name.
Server Port Optional
Value range:
1-65535
Format:
Integer
Default value:
80
It specifies the HTTP server port.
File URI
Mandatory
Value range:
N/A
Format:
String
Default value:
ota.bin
it specifies the URI of the firmware file on
HTTP server.
SSL Flag
Optional
Value range:
0,1
Format:
Integer
Default value:
0
It specifies the SSL flag where,
0- is for HTTP
1- is for HTTPs
Time Out
Optional
Value range:
1-1000000
Format:
Integer
Default value:
100
It specifies the HTTP server time out
value.
Table 292 FWUP HTTP Client Response
Responses
Remarks
OK
Success.
ERROR
If parameter is not valid.