UC864-G Hardware User Guide
DRAFT
- 29/10/07
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 15 of 66
4.2 Turning OFF the UC864-G
The turning off of the device can be done in three ways:
•
by software command (see UC864-G Software User Guide)
•
by hardware shutdown
•
by Hardware Unconditional Restart
When the device is shut down by software command or by hardware shutdown, it issues to the
network a detach request that informs the network that the device will not be reachable any more.
4.2.1 Hardware shutdown
To turn OFF UC864-G, first, you MUST cut off supplying power to the USB_VBUS pin, then the pad
ON# must be tied low for at least 2 seconds and then released.
The same circuitry and timing for the power on shall be used.
The device shuts down after the release of the ON# pad.
NOTE: To turn OFF UC864-G, first of all, you MUST cut off supplying power to the USB_VBUS, or the module does
not turn off
TIP: To check if the device has powered off, the hardware line PWRMON should be monitored. When PWRMON goes
low, the device has powered off.
4.2.2 Hardware Unconditional Restart
To unconditionally restart UC864-G, the pad RESET# must be tied low for at least 200 milliseconds
and then released.
The maximum current that can be drained from the ON# pad is 0,15 mA.
A simple circuit to do it is:
RESET#
Unconditional Restart
impulse
GND