![Telit Wireless Solutions LN940 WWAN M.2 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/telit-wireless-solutions/ln940-wwan-m-2/ln940-wwan-m-2_user-manual_1083697036.webp)
4. OPERTAING ENVIRONMENT
Table 6 Recommended Operating Conditions
Parameter
Min.
Typical
Max.
Storage Temperature
-30
°C
25
°C
85
°C
Recommended Operating Temperature
(3GPP Compliant)
-10
°C
25
°C
55
°C
Restricted Operating Temperature (*1)
(Operational, non-3GPP Compliant)
-20
°C
25
°C
70
°C
Extendable (with Limited Performance)(*2)
-40
°C
N/A
85
°C
Operating Voltage
3.135 V 3.3V
4.4V
(*1) Restricted Operation allows normal mode data transmission for limited time
until automatic thermal shutdown takes effect. Within the restricted temperature
range (outside the operating temperature range) the specified electrical
characteristics may be increased or decreased
(*2) A tolerance on the sated shutdown threshold may occur. The deviation is in
the range of +/-2
°C at the limits of over temperature and under temperature.
It may damage the M.2 Module when it is being operated under the condition
beyond its absolute maximum ratings (Table 7-1). Absolute maximum ratings
are limiting values to be considered individually when all other parameters
are within their specified operating ranges. Functional operation and
specification compliance under any absolute maximum condition, or after
exposure to any of these conditions, is not guaranteed or implied.
Содержание LN940 WWAN M.2
Страница 1: ...LN940 WWAN M 2 Engineering User Guide Rev 1 0 2017 06 23...
Страница 4: ......
Страница 5: ...APPLICABILITY TABLE PRODUCTS LN940A11 LN940A9...
Страница 6: ......
Страница 16: ...M 2 WWAN Module System Block Diagram Figure 2 2 1 System Block Diagram...
Страница 47: ...Figure RF Connector Specification Figure RF Receptacles Specification...
Страница 49: ...9 ACRONYMS NGFF Next Generation Form Factor...
Страница 50: ......
Страница 56: ......