Страница 1: ...TELIKOU Intercom System FT 800 4 Wire Eight Channel Main Station Instruction Manual TELIKOU Systems All Rights Reserved ...
Страница 2: ...le and reliable performance Flexible configurations easy operation full duplex communication clear and loud communication and strong noise resistance are just a few of the advantages of the FT 800 II Characteristics Announcement output Controllable background input Automatic circuit short protection and indication Feedback noise suppression Eight channels support Tally III Basic operation 1 Panel ...
Страница 3: ...light 1 Long Time Hold switch is connected When release the button switch is cut off 2 Short time press if button is lift or pressed quickly this switch is connected and self locking Press again switch is turned off 6 Talking Light Green light when talking 7 Program Feed Turn the switch on or off will send the external signal into intercom channels ON Active channels will receive external program ...
Страница 4: ... to all the channels 15 Listen LED When channel switch is lift or pressed this light on 16 Program Listen Volume Control Adjust program audio level which for the FT 800 panel speaker or headset 17 Panel Mic Gain Mic gain is used to adjust the panel microphone gain It has preset for electret microphones 18 AC Power Input Input Voltage 90V 260V Power Less than 35VA 19 Tally In for 1 4 Channel DB9F p...
Страница 5: ...utput Pin 6 Audio Input Pin 7 Green Tally Signal Drive Pin 8 Red Tally Signal Drive Note When connect to any other TELIKOU 4 wire device The RJ 45 connection cable should be made as follow Orange White Orange Green White Blue Blue White Green Brown White Brown Orange White Orange Blue Green White Green Blue White Brown White Brown Shield Shield 21 Channel Input Level Adjustment Used for balancing ...
Страница 6: ... Red Tally signal to channel 7 Pin 7 Green Tally signal to channel 8 Pin 8 Red Tally signal to channel 8 Pin 9 Common Note low level is efficient IV Connect to CCU CCU board is optional Each FT 800 can has max four CCU channel CCU channel can not talk with any other channel except front panel Pin 1 Ground Pin 2 Ground Pin 3 Audio Input Pin 4 Audio Output Pin 5 Audio Output Pin 6 Audio Input Pin 7 ...
Страница 7: ...1 High DC resistance in cable common 2 Headset cables are not well connected 1 Rewiring and check the cable 2 Check and reconnect the headset Hum or Buzz 1 Incorrect ground connection 2 Inductive pickup caused by close proximity to power lines or transformers 3 Headset cable is not wired properly 1 Check the earth connection 2 Relocate the offending unit 3 Rewire or change the cable distorted or l...
Страница 8: ... Wire Channel Input Audio Type Balanced 4 Wire Channel Output Audio Type Balanced 4 Wire Channel Input Impedance 10Kohm 4 Wire Channel Input Level 1Vp p 4 Wire Channel Output Level 1Vp p POWER SUPPLY AC 90 260V Power 45VA ENVIRONMENTAL 0 70 C 32 158 F Relative Humidity 0 90 DIMENSION 19 W x1 75 H x9 48 D 482mm x 44 5mm x 241mm WEIGHT 2 8kG Note Please be sure equipment is well connected to the gro...