(5-3) Reset: Sync-signal reset under partial-scan (Inner SW 1-4 ON)
When the inner V-reset switch (SW 1-4) is set in ON position, VD signal will be reset
immediately after image readout. This SW is enabled under 1/2 partial-scan mode only,
and works under internal sync operation mode.
V-reset OFF (Internal-sync)
VD signal: Normal 262.5H
VIDEO OUT
*1 Under 1/60 noninterlace mode 262K
V-reset ON (Internal-sync)
VD signal will be reset immediately after image readout.
Twice faster readout is obtained in comparison with the V-reset OFF mode.
VIDEO OUT
V-reset ON/OFF (External-sync)
Regardless of the V-reset ON/OFF, video output will be in sync with the external input,
EXT VT) signal
EXT. VD
VIDEO OUT
14
*1 Under 1/60 noninterlace mode 525H