QUICK INSTALL GUIDE 

 

 

Register for Telguard Service 

Register online a

www.telguard.com

 

Connect Dialer and Power to the TG-SCI Plus 

Connect the alarm panel’s dialer to the RJ-45 jack on the 

TGSCIPG01. If using the Single Line Interface Cable (SLIC) for 
power, connect the RJ-

45 cable’s orange wire to the alarm 

panel’s ground and its blue wire to the panel’s auxiliary power. If 
using the terminal block, connect the terminals closest to the RJ 
jack (labeled 

GND

 and 

DC IN

to the panel’s ground and power, 

respectively. 

 

Measure RSSI and Activate 

Apply power and press the RSSI button to put the LEDs 

into RSSI display mode. When you find a location that provides 
2 ½ bars or more (LEDs 4, 3 solid ON and 2 flashing), you are 
ready to activate. Press the RSSI button again to return the 
LEDs to normal display mode, and trigger and alarm from the 
panel. The first alarm will activate the unit with the TCC and will 
not be sent to the central station. When activation is successful, 
LED 1 will turn solid green. 

Finish Installation 

Send more signals and confirm delivery with central 

station. Use the provided hardware to mount the device. 