background image

8

3.

Attach the 

mounting template

 (supplied in box) to the window (customer 

assembly side) being sure to center the appropriate guide in the location identified 
in step 2. 

NOTE:

Use either the single large hole, or multiple small holes depending 

on which method you choose. Using the multiple small hole method 
with bullet-proof glass will afford maximum operator protection 
(Figure 4).

4.

Cut and/or drill the 

hole(s)

 from the customer assembly side.

5.

Have an assistant place the 

customer assembly

 against the window. Make sure 

the holes line up correctly. 

6.

Attach the 

mounting plate

 removed from the operator assembly (See Step 1) 

using the three (3) supplied mounting screws and rubber washers. (See Figure 5).

7.

Remove the lower left screw and washer and attach the ground wire (See Figure 6.

8.

Attach the 

cable harness

 from the customer assembly to the connector on the 

operator assembly (See Figure 6).

9.

Attach the 

operator assembly to the mounting plate

 using the screws removed 

in Step 1.

10.

Screw the 

threaded end

 of the ICW-6 power supply interface cord into the ICW-

6. 

The connector is located on the bottom of the ICW-6 on the operator assembly 

side.

 

11.

Secure the 

cord

 to the glass using wide clear adhesive tape.

12.

Connect the 

power supply to AC power

 using the supplied IEC cord. 

13.

Attach the 

ICW-6’s power cord

 to the power supply.

FIGURE 3.

Operator and Customer assemblies

Содержание ICW-6

Страница 1: ...ICW 6 Window Intercom Installation and Operation Instructions 93507855000 Rev C 11 2009 ...

Страница 2: ...2 467 3279 Factory Service 800 553 5992 Please include a note in the box which supplies the company name address phone number a person to contact regarding the repair the type and quantity of equipment a description of the problem and the serial number s Shipping to the Manufacturer All shipments of product should be made via UPS Ground prepaid you may request from Factory Service a different ship...

Страница 3: ...ntroduction 3 Unpacking and Inspection 3 Recommended Items 4 Specifications 4 Accessories 5 Installation and Operation 7 Installation 7 Operation 11 Inside and Outside Mic Adjustment Pot 11 Mic Adjustment Pot Location 11 ...

Страница 4: ......

Страница 5: ... and inspect for missing or damaged components You should have all of the items listed in Figure 1 ICW 6 Package A Cordset European B Cordset U S A C ICW 6 Final Assembly 1 Operator Side Assembly 2 Customer Side Assembly D Switching Power Supply E Installation Kit 6 screws 1 3 6 washers 3 Cable Tie F User Manual not shown G Mounting Template not shown H Quick Start Guide not shown I Warranty Card ...

Страница 6: ...puts External Speaker 2W 100dB SPL at 1ft at 1 kHz C weighting Internal Speaker 2W 100dB SPL at 1ft at 1 kHz C weighting Note These are sine wave maximums Voice measurements will range 70 to 90 dB SPL Headphones 80 mW 100dB peak SPL Voice Range 84 to 104 dB SPL Impedance 50 Ω Inputs Internal Panel Microphone Electret 4 mv at 1kHz typical into 1000 ohms source impedance External Headset Microphone ...

Страница 7: ...5 Accessories Description Part Number MCP 90 12 301029000 MCP 90 18 301030000 PH 88 IC3 300852300 PH 44 IC3 300853300 PH 88 IC3 QD 300853301 PH 44 IC3 QD 300853300 ...

Страница 8: ...6 ...

Страница 9: ...R 2 Installation and Operation Installation 1 Remove the two 2 screws holding the mounting plate to the operator assembly See Figure 2 2 Measure and identify the location where the intercom is to be mounted FIGURE 2 ICW 6 Assembly Detail ...

Страница 10: ...from the operator assembly See Step 1 using the three 3 supplied mounting screws and rubber washers See Figure 5 7 Remove the lower left screw and washer and attach the ground wire See Figure 6 8 Attach the cable harness from the customer assembly to the connector on the operator assembly See Figure 6 9 Attach the operator assembly to the mounting plate using the screws removed in Step 1 10 Screw ...

Страница 11: ...9 FIGURE 4 Mounting Template FIGURE 5 Customer Side Mounted ...

Страница 12: ...10 FIGURE 6 Connecting customer and operator assemblies prior to final mounting ...

Страница 13: ...nsitivity of the inside and outside mic This means the how far away from the microphone a person can stand to talk and still be heard Mic Adjustment Pot Location By default the following applies The inside mic is set midpoint 2 3 Speak Zone The outside mic is set midpoint 1 2 Speak Zone ...

Страница 14: ...12 FIGURE 7 ICW 6 Inside and Outside Mic Pot Location ...

Страница 15: ...tor side unit 2 Carefully remove the back plate from the operator side unit 3 Using Figure 7 locate the mic pot you want to adjust 4 With a flathead screwdriver turn the mic pot clockwise to increase the sensitivity OR Turn the mic pot counter clockwise to decrease the sensitivity FIGURE 8 Side Screws Holding the Back Plate to the Operator Unit ...

Страница 16: ......

Отзывы: