8
3.
Attach the
mounting template
(supplied in box) to the window (customer
assembly side) being sure to center the appropriate guide in the location identified
in step 2.
NOTE:
Use either the single large hole, or multiple small holes depending
on which method you choose. Using the multiple small hole method
with bullet-proof glass will afford maximum operator protection
(Figure 4).
4.
Cut and/or drill the
hole(s)
from the customer assembly side.
5.
Have an assistant place the
customer assembly
against the window. Make sure
the holes line up correctly.
6.
Attach the
mounting plate
removed from the operator assembly (See Step 1)
using the three (3) supplied mounting screws and rubber washers. (See Figure 5).
7.
Remove the lower left screw and washer and attach the ground wire (See Figure 6.
8.
Attach the
cable harness
from the customer assembly to the connector on the
operator assembly (See Figure 6).
9.
Attach the
operator assembly to the mounting plate
using the screws removed
in Step 1.
10.
Screw the
threaded end
of the ICW-6 power supply interface cord into the ICW-
6.
The connector is located on the bottom of the ICW-6 on the operator assembly
side.
11.
Secure the
cord
to the glass using wide clear adhesive tape.
12.
Connect the
power supply to AC power
using the supplied IEC cord.
13.
Attach the
ICW-6’s power cord
to the power supply.
FIGURE 3.
Operator and Customer assemblies
Содержание ICW-6
Страница 1: ...ICW 6 Window Intercom Installation and Operation Instructions 93507855000 Rev C 11 2009 ...
Страница 4: ......
Страница 8: ...6 ...
Страница 11: ...9 FIGURE 4 Mounting Template FIGURE 5 Customer Side Mounted ...
Страница 12: ...10 FIGURE 6 Connecting customer and operator assemblies prior to final mounting ...
Страница 14: ...12 FIGURE 7 ICW 6 Inside and Outside Mic Pot Location ...
Страница 16: ......