ANSI/CEA

-2028-

A

Safety Instructions:

LIGHTNING PROTECTION

  If  installed  outdoors,  be  sure  the  antenna  system  is 

grounded so as to provide protection against voltage 

surges and built-up static charges. Section 810 of the 

National  Electrical  Code  ANSI/NFPA70,  or  CSA  C22.1 

sections 10, 16, and 54, of the Canadian Electrical Code, 

provide information with respect to proper grounding 

of  the  mast  and  supporting  structure,  grounding  of 

the antenna lead-in wire to an antenna discharge unit, 

size  of  grounding  conductors,  location  of  antenna-

discharge  unit,  connection  to  grounding  electrodes, 

and  requirements  for  the  grounding  electrode  (see 

figure and instructions).

   Mount  the  lightning  arrestor  or  75  ohm  coaxial 

grounding block as close as possible to where the 75 

ohm coaxial cable downlead enters the house. 

  The ground wires for both the mast and the downlead 

should be copper or aluminum wire, number eight (8) 

or larger. 

  The downlead wire from the antenna to the lightning 

arrestor and the mast ground wire should be secured 

to the house, spaced from four (4) to six (6) feet apart. 

   In  the  case  of  a  “ground  up”  antenna  installation  it 

may not be necessary to ground the mast if the mast 

extends  four  or  more  feet  in  the  earth.  Consult  a TV 

serviceman for the proper depth in your location. 

WARNINGS

  To  prevent  fire  or  shock  hazard,  do  not  expose  the 

included power supply to rain or moisture. 

Antenna Lead 

in Wire

Example of antenna grounding as per 

National Electrical Code, ANSI/NFPA 70

NEC - National Electrical Code

Ground 

clamp

Electric Service

Equipment

Ground clamps

Power service Grounding Electrode System 

(NEC Art 250, Part H)

Antenna Discharge Unit

(NEC Section 810-20)

(May substitute a 75 ohm 

Coax Grounding Block)

Grounding  Conductors

(NEC Section 810-21)

    Installation  of  off-air  antennas  near  power  lines  is 

dangerous.  For  your  safety,  follow  the  installation 

instructions.

   Any alteration or modification to the product or usage 

not in accordance with product instructions voids the 

warranty.