EN
31
30
ii) If you choose to use the app to register your
H30Evolution, you first have to connect your
H30Evolution with your mobile device. To do that,
press BACK to leave the registration process for a
moment and follow the instructions explained in
the section
1.- Connection between the App and the
H30Evolution
.
Then turn your H30Evolution OFF, and then ON
again to start the Register process.
Select Settings->Register menu in the App.
Now you must disconnect your mobile device from
your H30Evolution and connect it to the internet.
Then it will be open a web browser with the
Televes Meter Registration web page. Register
your H30Evolution in our web. Once the process is
completed, you will get a PIN code by email.
Enter the PIN code in your H30Evolution:
2.4.4.- Clone
This function opens a web navigator with the web
page of your H30Evolution, and points directly to
the Clone section. See section
6.- Clone
of the
Web
Application
Error Messages
LOW BATTERY
Indicates that the battery is about to finish. The
battery icon is red now. It is recommended to
connect the meter to the external power source.
LOW BATTERY
Shutting down
Some time after the LOW BATTERY message
appears (time varies depending on the functions
used), it will appear this message. If the meter is
not connected to the external power source, it will
switch off.
BAD POWER
Unplug power source
This message appears when the meter is
connected to an external power source that does
not supply it the right power. Please, use only the
power source provided with the
H30Evolution
.
SHORT-CIRCUIT
Check installation
This message appears when the meter detects a
short-circuit at the RF input. It is recommended to
check the installation to find out why the short-
circuit is produced.
DC OUTPUT LIMIT EXCEED
Switch DC OUTPUT off
This message appears when the meter detects
an excessive consumption from the device that is
being powered. It is recommended to turn off the
powering feature of the
H30Evolution.
DC AT RF INPUT
Check installation
This message appears when the meter detects
DC at the RF input that is not generated by the
H30Evolution
. It is recommended to check the
installation.