Before handling or connecting the equipment, please read this manual.

•  

 

In order to reduce the risk of fi re or electric shock, do not expose the equipment 
to rain or moisture.

• No quitar la tapa del equipo sin desconectarlo de la alimentación.

• No obstruir las ranuras de ventilación del equipo.

•  Please allow air circulation around the equipment.

•  The equipment must not come into contact with water or even be splashed 

by liquids. Do not place containers with water on or near the equipment if it is 
not adequately protected.

•  Do not place the equipment near sources of heat or in excessively moisture 

conditions.

•  Do not place the equipment where it may be aff ected by strong vibrations or 

knocks.

•  

This symbol indicates that the equipment complies with the 

safety requirements for equipment of marked CE.

Inputs/Outputs/Connections description

The unit (

Fig. 1

) is provided with:

1.

    RF Input (12V/24V/Off  )

2. 

   RF Output (input loop-through)

3. 

   RF input (output loop-through)

4. 

   RF output

5. 

   Power BUS connectors

6. 

   Status LED

7. 

   Control BUS connectors

8. 

   Programmer / PC socket

Introduction

   It allows to select any channel in the VHF or UHF band (46-862MHz) and 

translate it in frequency to any position within these bands.

Technical specifi cations

NOTE

:  You have a complete User Guide on our website: 

www.televes.com.

 

      Links available at the end of this guide.

Down-Converter

Input frequency (selec.)

MHz

46 - 862

IN/OUT Connectors

tipo

“F” hembra

Input level 

dBμV 

50 a 80*

Input impedance

ohm. 

75

Frequency steps 
(selec.)

KHz

Analógico

250

Input line powering for preamps
(< 50 mA)

V

12 / 24 / OFF

Digital

166,66 / 125

Input loop-through gain

 dB

0 ± 3

F.I.

Bandwidth (selec.)

MHz

6 / 7 / 8

UP-Converter

Output frequency (selec.)

MHz

46 - 862

Output loop-through losses (typ.)

dB

< 1,5 

Frequency steps 
(selec.)

KHz

Analógico

250

Return losses (typ.)

dB

> 12 

Digital

166,66 / 125

IN/OUT Connectors

tipo

“F” hembra

Phase noise (typ.)

dBc/Hz 

80 @10KHz

Output impedance

ohm.

75

Output level

dBμV

80 ±5

Spurious level (min.)

dBc

60

Output level regulation

 dB

> 15

Slope regulation

dB

±3

General

Consumption (typ.)

mA

400 @ 24V

  (LNB power OFF)

450 @ 24V

  (LNB power ON)

Protection level

IP20

   

* Automatic gain for high level input signals.
These technical specifi cations are defi ned for a maximum ambient temperature of 45 ° C (113 ° F). For higher temperatures forced ventilation is required.

Содержание 564901

Страница 1: ...Ref 564901 w w w t e l e v e s c o m ES Procesador A D TWIN TWIN A D PROCESSOR Guía rápida Quick guide EN ...

Страница 2: ......

Страница 3: ... T PROCESSOR TWIN UCC T PROCESSOR TWIN UCC T PROCESSOR TWIN UCC T PRGM PROCESSOR TWIN UCC T PRGM PROCESSOR TWIN BROADBAND AMPLIFIER TEST 30dB UAMP44 1 2 CLAC 7234 4061 5071 5239 564901 5629 5575 RF RF UCC T CTRL PRGM PROCESSOR TWIN PWR 6 7 8 5 1 3 2 4 ...

Страница 4: ...rocesador permite seleccionar cualquier canal en la banda de VHF o UHF 46 862 MHz y colocardo igualmente en cualquier posición dentro de dichas bandas Características técnicas NOTA Dispone de un Manual de Instrucciones completo en nuestra web www televes com Enlaces disponibles al final de esta guía Down Converter Frecuencia de entrada selec MHz 46 862 Conectores de entrada salida tipo F hembra Ni...

Страница 5: ...sde cualquier menú extendido A SALIDA Ch C21 471 25 MHz Nivel 99 Vers FW Vx xx Vers Boot Vx xx TEMPERATURA Act 03 Max 04 reset IDIOMA MENUS IDIOMA Espa ol Reset CONFIG CDC ALIM PREAMP CONFIGURACION CONV AMP TABLA CAN FREC CONFIGURACION BW PENDIENTE EN CANAL CONFIGURACION A D OFFSET EN DIGITAL CONFIG Preamp off Dir CDC 123 CONFIG Preamp off Dir CDC 123 A CONFIG Tab canales Frecuencia Conversor A CO...

Страница 6: ...D 7 Control BUS connectors 8 Programmer PC socket Introduction It allows to select any channel in the VHF or UHF band 46 862MHz and translate it in frequency to any position within these bands Technical specifications NOTE You have a complete User Guide on our website www televes com Links available at the end of this guide Down Converter Input frequency selec MHz 46 862 IN OUT Connectors tipo F h...

Страница 7: ...xtended menu A OUTPUT Ch C21 471 25 MHz Level 99 FW Vers Vx xx Boot Vers Vx xx TEMPERATURE Now 03 Max 04 reset LANGUAGE MENU LANGUAGE English Reset CDC CONFIG PREAMP POWER CONV AMP CONFIGURATION CH FREQ TABLES BW CONFIGURATION CHANNEL SLOPE A D CONFIGURATION OFFSET IN DIGITAL CONFIG Preamp off Addr CDC 23 CONFIG Preamp off Addr CDC 123 A CONFIG Chan table Frequency Converter A CONFIG Chan table Fr...

Страница 8: ... garantía los daños provocados por uso indebido des gaste manipulación por terceros catástrofes o cualquier causa ajena al control de Televés S A Garantia Televés S A off ers a two year guarantee beginning from the date of purchase for countries in the EU For countries that are not part of the EU the legal guarantee that is in force at the time of purchase is applied Keep the purchase invoice to d...

Страница 9: ......

Страница 10: ......

Страница 11: ...11 Instrucciones de uso ES www televes com sites default files HTE 564901_es pdf User instructions EN www televes com sites default files HTE 564901_en pdf ...

Страница 12: ......

Отзывы: