Additional Support

Teletronics International, Inc. is pleased to provide software and integration support to customers
desiring to develop special WINC 2400C applications.  Teletronics’ personnel will assist you in
developing functional and technical requirements for your specific application and will work with
you in implementing cost effective solutions.  Please contact Teletronics directly  to discuss your
particular needs.

Содержание WINC 2400C

Страница 1: ...WINC 2400C Wireless Modem Owner s Manual TELETRONICS INTERNATIONAL INC 1803 Research Blvd Suite 404 Rockville Maryland USA 20850 3155 Tel 301 309 8500 Fax 301 309 8851 E mail tiusa teletronics com...

Страница 2: ...II Serial Number Remote Units Serial Number Remarks...

Страница 3: ...ed No part or parts of this document may be reproduced translated stored in any electronic retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or o...

Страница 4: ...tenance by any person or party other than a Teletronics International Inc employee or authorized service facility or any use in violation of instructions furnished by Teletronics International Inc Thi...

Страница 5: ...THE CONCEPT OF SYNCHRONOUS CONFIGURATION 12 5 2 SYNCHRONOUS CONFIGURATION 14 5 3 BROADCAST CONFIGURATION 17 APPENDIX A AT COMMAND SET 20 COMMONLY USED AT COMMANDS WITH THE WINC 900C 21 APPENDIX B WINC...

Страница 6: ...st 3 different radiation power levels are offered either 50mW 100mW or 500mW Please check the product sheet that comes with the WINC 2400C you purchased Depending on the material of walls and ceilings...

Страница 7: ...and is defined by the right most seven 7 digits of the serial number The device address can also be found by using the ATI0 command to be further discussed in Appendix A A DB 25 female connector is u...

Страница 8: ...1 Turn your computer off before starting 2 Connect the asynchronous configuration port of the WINC 2400C to your computer s serial port using an RS 232 DB 9 connector and associated cable Cable with D...

Страница 9: ...9 After the self test you are now ready to do the configuration This will be presented in the next section...

Страница 10: ...communication software to meet default value of configuration port on the WINC 2400C a Click on the available serial port from the Connector list b Click on the 9600 from the Baud Rate list c Click o...

Страница 11: ...ing process above to make sure that 9600 is the default baud rate on WINC 2400C 4 Please work from the beginning of chapter 4 0 again 5 If you still have problems communicating with the WINC 2400C Ple...

Страница 12: ...by selecting alternatives from a series of menus via the DB 9 configuration port In this section the menu selection procedure is detailed The Main Menu is selected by issuing the AT command AT 2 from...

Страница 13: ...ain Menu is exited upon choosing this option To get back to the Main Menu you must issue the AT 2 command from the terminal mode 7 Exit Select this option to exit from the Main Menu 5 2 Synchronous Co...

Страница 14: ...attern 31 chips Master Slave Operation Interface Type Preamble Code Pattern 31 chips 9 6 19 2 38 4 56 0 57 6 64 0 72 0 96 0 128 EXIT RS 232 V 35 RS 422 EXIT INT EXT EXIT INT EXT EXIT ENTER EXIT 0 2404...

Страница 15: ...umber Operating in the synchronous mode twenty 20 4 MHz channels are available for communications After you make your selection you must coordinate that choice with the distant end and use this menu t...

Страница 16: ...er address in the configuration setting has to be set to the master station s address Otherwise the slave station can not filter the transmitted message from master station This master address and bro...

Страница 17: ...ree packets are passed to the DTE FEC ON or whether all packets are passed FEC OFF i e even those packets with known errors are passed to the DTE A Change Master Slave mode For proper operation of the...

Страница 18: ...preted by the DCE only when in the command state All command lines have a prefix a body and a terminator The prefix consists of the characters AT and the body is a command string restricted to the pri...

Страница 19: ...represents the destination address The local address can be verified using the ATI command where ATI0 refers to the equipment identification number or local address Please refer to the following tabl...

Страница 20: ...ence whereas red indicates an inactive state or signal absence The configuration of the two rows of LEDs is shown above and the table below indicates the function of each signal beginning with the lef...

Страница 21: ...Solid ON indicates sufficient signal strength while solid OFF indicates either no received signal or a signal too weak to sustain communications A blinking signal indicates a marginal signal level If...

Страница 22: ...S 232 DB 25 female synchronous Port 2 RS 232 DB 9 male asynchronous Compatibility Hayes AT Command Set Radio Frequency Band 2404 2483 MHz transmit and receive at ISM band Channelization 24 independent...

Страница 23: ...l TX Clock Pin 1 2 3 4 5 6 7 8 DCD TXD RXD DSR GND DTR CTS RTS Designation Direction IN OUT IN OUT IN OUT IN Function Data Carrier Dectect TX Data RX Data Data Set Ready Signal Ground Data Terminal Re...

Страница 24: ...n Direction RAD Kilomux 2000 Winchester Type 1 TXC B EXT Z 2 RXD A P 3 TXD A R 4 CTS A C 5 RTS A D 6 DTR A E 7 GND B 8 DCD A F 9 TXC B INT X 11 RXC B EXT W 12 RXC B INT AA 14 RXD B S 15 RXC A INT Y 16...

Страница 25: ...stomers desiring to develop special WINC 2400C applications Teletronics personnel will assist you in developing functional and technical requirements for your specific application and will work with y...

Страница 26: ...26...

Страница 27: ...27 Printed in the USA Teletronics International Inc 24C0313 doc 1803 Research Blvd Suite 404 Rockville MD 20850 3155 USA...

Отзывы: