Voice Guide Keypad - LED63VG User Manual
5
of these substances may lead to
fire.
No liquids should enter the interior.
Overview
The LED63VG Keypad is designed
to control the CA60Plus Control
Panel and provides the user with
system status information.
The Control Panel is fully program-
mable with the LED63VG keypad.
An LED indication on the keypad
visualizes the system status and
alarm events information.
A sound buzzer informs the user
about correct or incorrect key en-
tries as well as activated alerts.
Seven voice messages provide the
user with addition information.
Sound Indication
There are seven different sound
combinations that indicate seven
different conditions:
• Click – single short beep indicat-
ing the pressing of a key;
• Confirm – two long sound sig-
nals, indicating the system confir-
mation to a successfully executed
operation;
• Reject – a single long beep, indi-
cating an incorrectly executed op-
eration;
• Entry time – continuous beep, in-
dicating intrusion into an entrance
zone;
• Exit time – short beeps, indicat-
ing the system is armed and the
user is required to leave the en-
trance zone. Ten seconds before
the exit time is over beep frequency
increases;
• Technical problem – two short
beeps, indicating a technical prob-
lem;
• Chime – short beeps with subse-
quently increasing frequency, indi-
cating intrusion into a zone with an
activated chime option;
Voice Messages
There are seven different voice
messages that indicate different
conditions:
•
“System is armed”
•
“System is disarmed”
•
“Please enter your code to dis-
arm”
•
“AC power is lost”
•
“Battery is discharged”
•
“Please leave the premises”
•
“Alarm in the system”
Voice Guide Keypad - LED63VG User Manual
20
Bypassing
To execute a bypass operation the
manager is required to enter his
personal code:
CODE
PRG
4
0
Pressing a numeric key bypasses
the respective zone. The display
LED, corresponding to the zone
number, lights up permanently.
Pressing the same key once again
de-bypasses the zone and the LED
goes out.
The selected programming is con-
firmed by pressing the
ENT
key.
Bypassing sequence (e.g. zone 2):
2
2
ENT
2
Setting the Clock
To set the clock the manager is re-
quired to enter his personal code.
The set entries are visualized in
binary-hexadecimal form.
Key sequence for setting the
clock:
CODE
PRG
5
0
(2 beeps)
NEW
TIME
(HHMM)
ENT
Setting the Date
To set the date the manager is re-
quired to enter his personal code.
The set entries are visualized in
binary-hexadecimal form.
Key sequence for setting the
date:
CODE
PRG
5
1
(2 beeps)
NEW
DATE
(DDMM)
ENT