LINE TESTING

(1) Identify the pair at the customer end.
(2) Insert Probe leads and connect to the identified pair.  Press
a Probe button to change the Oscillator to the selected mode.
(3) 

Open Circuit.

  Oscillator tone is disconnected and line is left

open  circuit.    After  disconnecting  Probe  leads  from  line,
insulation resistance tests may be done on the open line.
(4) 

Short  Circuit.

    Oscillator  tone  is  disconnected  and  line  is

looped.  White wire is also shorted to line.  After  disconnecting
Probe leads from line, loop resistance may be measured.
(5) 

Exchange  Connect.

    Oscillator  tone  is  disconnected  and

line  is  connected  through  to  exchange.    Green  LED  on  Probe
indicates that 48Vdc is connected to line.

FAULT LOCATION

Two Wire Test

Used with a single pair containing one good wire and the faulty
wire.
(1) Disconnect the pair under test from the exchange.
(2)  Connect  the  Blue  Oscillator  leads  to  the  pair  under  test
(white lead not used).
(3)  At  the  customer  end  identify  the  pair  and  press  OPEN  to
disconnect the oscillator from line.
(4)  Disconnect  Probe  Leads  and  test  the  line  to  identify  the
faulty wire.
(5) Press SHORT to loop line then carry out fault location.

Three Wire Test

(1) As for Two-Wire Test but connect  the Blue leads to  a good
pair  and  the  White  lead  to  the  faulty  wire.    Note  that  in  Short
Circuit Mode, all three wires are looped at the Oscillator.

Pulse Echo Test (PET)

The  loop  /  unloop  facility  can  be  used  to  calibrate  a  PET  for
length of line to Oscillator.