User Manual
CXE180
59300401
Rev.001
26.5.2010
7(12)
Powering
The supply voltage of the remote power
ed amplifier (26...65 V AC) can be fed
through either f the output ports (Figure 1 pos. 3 & 4) or the input port (Figure 1
pos. 1). Make sure the remote powering jumpers (Figure 4 pos. 20 & 21) are in
the correct positions for remote powering. Refer to chapter ‘Jumper settings’
.
External power can also be fed through the amplifier into the network by moving
remote powering jumpers of the output ports to “on” position. Maximum feed-
through current is 3 A per port (6 A total). When F connector is used, a remote
current should be lower than 2 A.
Note that the external wiring connected to terminals that are hazardous live
requires installation by an instructed person. Because the amplifier is not
equipped with an all-pole mains switch, the powering shall be carried out in
accordance with all applicable installation rules.
The power intake of the remote powered amplifier may also be done externally
via the cable feed-through that is located on the upper right corner of the
amplifier (see Figure 3). The protective fuse is located on the left hand side of
the power supply board.
8907016
AC
GND
FUSE
Figure 3. Remote cable connector
The locally powered CXE180 amplifier is connected to the main voltage of
180
…255 V AC via its own power cord. The power supply is double shielded
and does not require separate grounding. However, the amplifier housing has to
be grounded from the grounding point. The supply voltage fuse
(T3.15 A / 250
V)
is located on the upper right corner of the amplifier,
underneath the remote cable connector (Figure 3).