CRT103 stand-alone installation
The units can be installed for stand-alone use by using a
CMA015
(installation for one 5HP wide units) module adapters. To insert a
CRT103
card unit into the module adapter, push the unit along the guide
rails into module until the unit is firmly attached. Secure the plug-in unit
with the upper and lower locking screws. The stand-alone unit should be
mounted to a vertical surface.
The permitted supply voltage range is 10.5...14 VDC. The current
consumption is 300 mA. The permitted operational temperature range is
-34...+74°C.
Note!
Alternatively the units can be installed for stand-alone use by
using a
CMA025
(installation for two 5HP wide units) or
CMA035
(installation for three 5HP wide units) module adapters.
The 12V DC supply voltage is supplied by the means of a separate
mains adapter with a regulated output, (e.g.
CPS251
).
Please refer to
separate documention for module adapters and mains adapters.
For limited space installation the
CMA015/025/035
module adapters can
be rear-mounted by means of an optional installation kit
CIK002
.
CPS251
12VDC mains adapter.