Teleskop-Service TSEQ25 Скачать руководство пользователя страница 7

7

Equatorial mount TSEQ25

User manual

If the tube is not in balance, first clamp the 
Dec axis with the tube in a horizontal position. 
Slightly loosen the clamping screw(s) of the 
tube clamp. Move the tube to compensate 
for the imbalance. To check, loosen the Dec 
axis again and again while holding the tube to 
prevent unintentional swiveling. 
Tighten the clamping screw of the tube 
clamp(s) when the tube is balanced.

Now slew the tube to the position shown in 
the adjacent picture (parallel to the RA axis). 
The inclination may differ from that shown in 
the image.

Make sure that the Dec axis (clamping screw 
c) is locked and open the clamping screw of 
the RA axis (d).
Loosen the clamping screw of the counter-
weight. Swivel the telescope until the Dec-
axis is horizontal. Hold the counterweight to 
prevent it from slipping on the rod.
Find the counterweight position where the 
weight and telescope are balanced and 
clamp the weight at this position. It should no 
longer be possible to move it. Return the tele-
scope to the position shown in the first image 
on this page and clamp the RA axis.
Your telescope is now balanced on the 
mount.

Содержание TSEQ25

Страница 1: ...1 Equatorial mount TSEQ25 User manual User manual Equatorial mount TSEQ25...

Страница 2: ...crack and cause you to lose your eyesight Also please do not use the telescope for solar projection The heat generated inside may destroy the telescope eyepiece Never leave the telescope unattended e...

Страница 3: ...nual show a different mount Overview a Declination fine adjustment b Right ascension fine adjustment c Clamping of the declination axis d Clamping of the right ascension axis e Counterweight f Clampin...

Страница 4: ...d head using the screws provided Make sure that the holders for the storage plate face inwards Plug the storage plate and holder together as shown in the picture and lock the connection by turning the...

Страница 5: ...f the axis Attach the counterweight rod and turn the mount head so that the rod points down wards Then lock both axes with the clamping screws Then remove the knurled screw at the lower end of the cou...

Страница 6: ...ibrium To do this set up the telescope with the mount so that you have enough space to slew the telescope without the tube hitting objects in the vicinity Now first open the clamping screw on the uppe...

Страница 7: ...jacent picture parallel to the RA axis The inclination may differ from that shown in the image Make sure that the Dec axis clamping screw c is locked and open the clamping screw of the RA axis d Loose...

Страница 8: ...ing the RA axis Look along the Dec axis If this axis points to Polaris you have aligned your mount accu rately enough for visual observing You can now loosen the axis clamps and slew the telescope to...

Страница 9: ...tude east or west angular distance from the prime meridian In the sky declination corresponds to latitu de Thereby stands for the northern for the southern hemisphere The longitude is represented by t...

Страница 10: ...aft making sure that the grub screw is positioned over the flattened side of the shaft Carefully tighten the grub screw 5 Slide the motor shaft onto the flexible coupling and rotate the motor unit so...

Отзывы: