Telesis TMC600 Скачать руководство пользователя страница 8

 
 

 

TMP4500E/TMC600 Marking System

 

 

78811A 

© 2014  Telesis Technologies, Inc. – All Rights Reserved

 

8 of 9 

Host Communications  

(continued)

 

Extended Protocol.

  This protocol selection includes error checking and transmission acknowledgment. It should be used in applications 

where serial communication is a vital part of the marking operation. All communications are carried out in a parent/child relationship with 
the host being the parent. Only the host has the ability to initiate communications. If the host does not receive a response within three 
seconds, it should re-transmit its original message. If no response is received after three tries, it should declare the link to be down. 

The following describes the Extended Protocol message format as sent from the host  to the TMC600 controller 

 

SOH  TYPE  [##]  STX  [DATA]  ETX  BCC  CR 

 

 

Where: 

SOH

 

ASCII Start of Header character (001H). The controller 

ignores all characters received prior to the SOH. 

TYPE

 

A single, printable ASCII character that defines the 

meaning (type) and content of the message 
downloaded from the host, where: 

1  Message Type 1 overwrites a specific field in 

currently loaded pattern with data supplied in the 
host message. See [DATA] for details. 

P  Message Type P specifies the pattern name to be 

loaded for printing. See [DATA] for details. 

Q  Message Type Q updates a specific query buffer 

with data supplied in the host message.  
See [DATA] for details. 

V  Message Type V updates the variable text in a 

specific text field of the currently loaded pattern 
with data supplied in the host message.  
See [DATA] for details. 

O  Message Type O resets marker and places it 

online 

G  Message Type G initiates a print cycle to mark the 

currently loaded pattern 

Message Type I requests the marker return the 

status of standard output and input signals. The 
system will return a hexadecimal code for the 6 
output signals and 12 input signals in the following 
format: 

O O ; I I I  

where: 

bit 1 

READY 

0x01 

bit 2 

DONE 

0x02 

bit 3 

PAUSED 

0x04 

bit 4 

SPARE_1 

0x08 

bit 5 

SPARE_2 

0x10 

bit 6 

SPARE_3 

0x20 

bit 1 

START 

0x001 

bit 2 

STOP 

0x002 

bit 3 

SEL_0 

0x004 

bit 4 

SEL_1 

0x008 

 bit 5 

SEL_2 

0x010 

bit 6 

SEL_3 

0x020 

bit 7 

SEL_6  

0x040 

bit 8 

SEL_4 

0x080 

bit 9 

SEL_5 

0x100 

bit 10  SPARE_1 

0x200 

bit 11  SPARE_2 

0x400 

bit 12  SPARE_3 

0x800 

 

Input SEL_6 may be configured  to place machine 
online (default) or for Remote Pattern Selection. 

 
 

 

 

{##] 

Optional two-digit ASCII number that specifies the 

Station ID of the controller when used in multi-drop network 
applications. The Station ID may range from 00-31. Note that “00” 
is reserved for applications where only one controller is used. In 
such applications, this field may be eliminated and “00” will be 
assumed. 

STX 

ASCII Start of Text Character (002H). 

[DATA] 

Optional character string that may be required for 

certain message types (e.g., Type 1, P, Q, and V). 

 

Typically, data is sent in the format: 

n n < s t r i n g >

 

where: 

 

nn  =  two-digit field number or query text 

buffer where data will be placed.  

Note

: Not used with Message Type P. 

 <string>  =  For Message Type P, indicates the 

pattern name to be loaded. 

 

    For Message Types 1, Q, or V, 

indicates the data to be inserted into the 
field or the query text buffer, as 
applicable. 

ETX 

ASCII end of text character (003H). 

BCC 

Optional Block Check Code that is generated and sent 

to improve link reliability by providing fault detection. 
The BCC is calculated by taking an eight bit addition of 
the TYPE and DATA TEXT characters and transmitting 
them as a three digit ASCII decimal number in the 
range from 000 to 255. If the sum is greater than 255, 
the most significant bit overflows and is discarded.  

CR 

ASCII Carriage Return Character (00DH). 

 

 
 
 
 
 
 
 
 

 

Содержание TMC600

Страница 1: ...used in virtually any orientation The integral standoff with its padded front surface is held against the marking surface while marking The standoff can be adjusted forward and aft to change the pin...

Страница 2: ...d panel mounted or enclosure mounted unit as applicable 3 Ensure controller power switch is OFF 4 Connect marker cable to controller 5 Connect power cable to controller 6 Position controller power swi...

Страница 3: ...Such variables will alter the actual noise level Despite detailed guidance provided with each machine variable operating conditions are beyond the control of Telesis The responsibility of establishing...

Страница 4: ...00 lb 3 18 kg controller only 7 21 lb 3 28 kg with wall mount kit Operating Temp 32 to 104 F 0 to 40 C Operating Humidity 10 to 80 non condensing Power Requirements 115 230 VAC 3 1 5 amps 50 60 Hz si...

Страница 5: ...the TMC600 controller It is a graphical user interface that makes pattern marking and pattern design quick and easy The WYSIWYG what you see is what you get interface provides a to scale image of the...

Страница 6: ...the MerlinTouch PS software is specifically designed to display on the controller s integrated high resolution touch screen monitor optional Auxiliary Axis Interface The Auxiliary Axis Port allows the...

Страница 7: ...haracter specifies where the software begins to count character positions This number must be entered in decimal format e g 2 for ASCII Start of Text STX Terminating Character identifies the end of tr...

Страница 8: ...pe I requests the marker return the status of standard output and input signals The system will return a hexadecimal code for the 6 output signals and 12 input signals in the following format O O I I...

Страница 9: ...ted States and other countries Intel is a registered trademark of Intel Corporation in the United States and other countries MicroPin is a trademark of Telesis Technologies Inc in the United States NE...

Отзывы: