![Telephone Technical Services DP3-AH Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/telephone-technical-services/dp3-ah/dp3-ah_user-manual_1082110013.webp)
Telephone Technical Services
Page 13
The
RED WIRE
of the connection box, carries one leg of the Audio
Signal. It must connect to EITHER centre position (pin 2 or 3) of the
supplied Phoenix plug. Note - Polarity is not important.
The
GREEN WIRE
of the connection box, carries the other leg of the
Audio Signal. It must connect to EITHER centre position (pin 2 or 3) of
the supplied Phoenix plug. Note - Polarity is not important.
The
BLACK WIRE
of the connection box, carries one leg of the 12V
Power input. It must connect to EITHER outer position (pin 1 or 4) of
the Phoenix plug. Note - Polarity is not important.
The
YELLOW WIRE
of the connection box, carries one leg of the 12V
Power input. It must connect to EITHER outer position (1 or 4) of the
Phoenix plug. Note - Polarity is not important.
Where Two Door Phones are to be used, they should both connect
to the same contacts of the interface box (ie: parallel connection).
The
ORANGE and BROWN WIRES
of the connection box connect to
the Internal Relay used for Lock 1. Connect ONE leg of the 12V power
for Lock 1 to these terminals, by cutting the wire in half and fit one part
to the screw terminal connecting to the Orange wire and the other to
the screw terminal connected to the Brown wire. Polarity is not important.
The
BLUE and WHITE WIRES
of the connection box connect to the
Internal Relay used for Lock 2. Connect ONE leg of the 12V power for
Lock 2 to these terminals, by cutting the wire in half and fit one part to
the screw terminal connecting to the Blue wire and the other half to the
screw terminal connected to the White wire. Polarity is not important.
BYPASS CONNECTION BOX
If you don’t plan to use the connection box, then you can connect the
CAT5 cable direct to the DS Control unit and Door Phone, as follows :
AUDIO CONNECTION (polarity is not important)
The centre 2 pins of the DS Controller RJ socket need to
connect to the centre 2 positions of the DP2 Phoenix socket.
POWER CONNECTION (polarity is not important)
The 2 pins either side of the centre 2 pins of the DS Controller socket
connect to the 2 outer positions of the 4 pin Phoenix socket.