Page 198
& hook flash
The & dial modifier issues a hook flash signal — the modem hangs up for a short period. Hook
flashes are commonly used with PABXs to transfer calls.
For example:
To dial 0, hook flash and then dial 12345:
• Type: CRN0&12345 <E>
: wait for dial tone
The : modifier causes the modem to wait for a dial tone before dialling. If the modem does not
detect a dial tone within 30 seconds, it returns a message of CFI AB, hangs up and returns to
local command state.
You can change the dial tone waiting period from the default period of 30 seconds by changing
the value in Register 7.
☞
☞
☞
☞
☞
When using the : modifier, the length of time your modem waits for a dial tone is
determined by the value contained in S Register 7 (Wait for Carrier) and not the
value in S Register 6 (Wait for Dial Tone).
☞
☞
☞
☞
☞
UK Modems. Setting S Register 7 with a value above 58 may invalidate the
approval of your modem. S Register 7 must be set to 20 before issuing the : dial
modifier.
For example:
To wait for a dial tone and then dial 111-0123:
•
Type: CRN:1110123 <E>
See Also
CRS command
Dial Stored Number
S Register 6
Wait Time for Dial Tone
S Register 7
Wait Time for Carrier
S Register 8
Length of Dial Pause
Содержание Global Carrier
Страница 1: ...Global Carrier 56 Modem User s Guide 0049 2200 001 Rev A...
Страница 85: ...ATCommands Page 85 See Also A Command Answer B Command Select Communication Standard D Command Dial MS Command...
Страница 120: ...Page 120 Range 0 2 4 See Also D command Controlling DTR X command Synchronous Clocks Z command Stored Phone Number...
Страница 130: ...Page 130 Range 0 2...
Страница 225: ...S Registers Page 225 See Also ATS105Voice Dead man Timer Range 0 255...
Страница 252: ...Page 252 Standard RS 232 Examples...
Страница 262: ...Page 262...
Страница 289: ...Compliances Page 289...