APPENDIX
51
Meter Resolution Voltage
10mV or 100mV
current
1mA or 10mA
2mA or 10mA (T3PS13206)
Display
LCD
4.3" single color LCD display
Ammeter
3.200A full scale, 4 digits or 3 digits
6.200A full scale, 4 digits or 3 digits
(T3PS13206)
Voltmeter
33.00V full scale, 4 digits or 3 digits
Accuracy
Setting/
Read back
Accuracy
Voltage: ±0.1% of r 30mV(4 digits)
±0.1% of r 200mV(3digits)
Current: ±0.3% of r 6mA(4 digits)
±0.3% of r 20mA(3 digits)
±0.3% of r 10mA)(4 digits,
for T3PS13206)
±0.3% of r 20mA)(3 digits,
For T3PS13206)
CH3 on the
T3PS33203
Output Voltage
5V, ±5%
Output Current
5A
Line
≤
3mV
Load
≤
10mV
Ripple & Noise
≤
2mVrms (5Hz ~ 1MHz)
Insulation
Chassis and Terminal 20M
Ω
or above (DC 500V)
Chassis and AC cord 30M
Ω
or above (DC 500V)
Operation
Environment
Indoor use, Altitude:
≤
2000m
Ambient temperature: 0 ~ 40°C
Relative humidity:
≤
80%
Installation category: II
Pollution degree: 2
Storage
Environment
Ambient temperature: -10 ~ 70°C
Relative humidity:
≤
70%
Power Source
AC 100V/120V/220V±10%, 230V+10%/-6%, 50/60Hz
Accessories
Quick Start Guide x1, Power Cord x 3
Test lead: T3PS13206: GTL-104A x1, GTL-105A x1
T3PS23203: GTL-104A x2
T3PS33203: GTL-104A x3
T3PS43203: GTL-104A x2, GTL-105A x2
Dimensions
210 (W) x 155 (H) x 306 (D) mm