177
9.
CALIBRATION PROCEDURES
This section contains information for calibrating the T200 as well as other supporting
information. For information on EPA protocol calibration, please refer to Section 10.
This section is organized as follows:
SECTION 9.1 – Before Calibration
This section contains general information you should know before about calibrating
the analyzer.
SECTION 9.2 – Manual Calibration Checks and Calibration of the T200 Analyzer in its
Base Configuration
This section describes:
The procedure for checking the calibrating of the T200 and calibrating the
instrument with no zero/span valves installed or if installed, not operating. It
requires that zero air and span gas be installed through the Sample port.
Instructions for selecting the reporting range to be calibrated when the T200
analyzer is set to operate in either the IND or AUTO reporting range modes.
SECTION 9.3 – Manual Calibration with the Internal Span Gas Generator
This section describes:
The procedure for manually checking the calibration of the instrument with
optional internal span gas generator installed.
The procedure for manually calibrating the instrument using the optional
internal span gas generator.
SECTION 9.4 – Manual Calibration and Cal Checks with the Valve Options Installed
This section describes:
The procedure for manually checking the calibration of the instrument with
optional zero/span valves option installed.
The procedure for manually calibrating the instrument with zero/span valves
and operating.
Instructions on activating the zero/span valves via the control in contact
closures of the analyzers external digital I/O.
SECTION 9.5 – Automatic Zero/Span Cal/Check (AutoCal)
This section describes:
The procedure for using the AutoCal feature of the analyzer to check or
calibrate the instrument.
The AutoCal feature requires that either the zero/span valve option or the
internal span gas generator option be installed and operating.
06858E DCN7057
Содержание T200
Страница 2: ......
Страница 4: ...ii This page intentionally left blank 06858E DCN7057 ...
Страница 8: ...vi This page intentionally left blank 06858E DCN7057 ...
Страница 344: ...Index Teledyne API T200 NO NO2 NOX Analyzer Operation Manual 342 This page intentionally left blank 06858E DCN7057 ...
Страница 380: ...This page intentionally left blank B 2 06858E DCN7057 ...
Страница 384: ...This page intentionally left blank B 6 06858E DCN7057 ...
Страница 387: ...APPENDIX D Wire List and Electronic Schematics 06858E DCN7057 D 1 ...
Страница 388: ...This page intentionally left blank D 2 06858E DCN7057 ...
Страница 393: ...06858E DCN7057 D 7 ...