Figure 2.98: Protocol Errors Dialog
Set the Saving Voltage/Current Time Interval duration. Check the applicable Voltage value
that you want the Analyzer to save. See
“Power Tracker View (SATA only)” on page 273
for
more information.
Protocol Error Mask
Click the Protocol Error Mask button to open the Protocol Error Mask dialog (see
).
Figure 2.99: Protocol Errors Dialog
Check the Protocol Errors that you want the Analyzer to ignore.
When “RD Error” and “Code violation Error” are set as trigger events:
“RD Error” or “Code violation Error” can occur right after the OOB sequence.
“RD Error” or “Code violation Error” can occur right after the recovery from the PM state.
These errors are mainly caused by the long synchronization time of the analyzer. If these
errors, caused by the Analyzer, become triggers, you cannot detect some other errors
that you really need to detect. To NOT detect the above two errors, enable the software
setting
Disable