Safety Considerations 

 
Potential safety hazards exist unless 
proper precautions are observed when 
working with this unit. To ensure safe 
operation, the operator must follow the 
information, cautions and warnings pro-
vided in the Operations Manual, and 
observe the warning labels placed on the 
unit itself. 
 

High Voltage Hazards 

 
High voltage is any voltage in excess of 
30V. Voltages above this value can be 
hazardous and even lethal under certain 
circumstances. Care should be taken 
when working with devices that operate 
at high voltage. 

Electrical Discharge Hazards 

 
An electric spark can not only create 
ESD reliability problems, it can also 
cause serious safety hazards. Follow all 
ESD precautions when working with this 
unit. 
 

High Current Hazards 

 
Many high power devices are capable of 
producing large surges of current. This is 
true at all voltages, but needs to be em-
phasized for low voltage devices. Low 
voltage devices provide security from 
high voltage hazards, but also require 
higher current to provide the same pow-
er. High current can cause severe injury 
from burns and explosion. 

Warranty 

 
Refer to the manufacturer’s warranty 
document for specific warranty coverage 
by product. The warranty does not apply 
to any goods that, upon examination by 
the manufacturer, are found to have been 
(i) mishandled, misused, abused, or dam-
aged by the Buyer or Buyer’s customer, 
(ii) altered from their original state, (iii) 
repaired without the manufacturer’s prior 
written approval, or (iv) improperly 
stored, installed, operated, or maintained 
in a manner inconsistent with the manu-
facturer’s instructions. This warranty 
does not apply to defects attributed to 
normal wear and tear. 

Teledyne Paradise Datacom LLC 

 

 

Teledyne Paradise Datacom Ltd. 

328 Innovation Blvd., Suite 100 

 

2&3 The Matchyns, London Road, Rivenhall End 

State College, PA 16803 USA 

 

Witham, Essex CM8 3HA United Kingdom 

Tel: (814) 238-3450 

 

 

Tel: +44(0) 1376 515636 

Fax: (814) 238-3829 

 

 

Fax: +44(0) 1376 533764 

www.paradisedata.com 

Use and Disclosure of Data 

 
The information contained herein is classified as EAR99 under the U.S. Export Administration Regulations. Export, re-export or diversion 
contrary to U.S. law is prohibited. Specifications are subject to change without notice. 

of Form C relay contacts are available at this port as a 
Service Request. Baud rate and other communication 
parameters are selectable via the front panel menu.  

A RJ45 connector is also available at Port J9 for com-
munication with the controller over Ethernet. This port 
becomes the primary remote control interface when 
the Interface option is selected to “IPNet” as described 

in the Operations Manual. This feature allows the user 
to connect the RCP to a 10/100 Base-T office Local 
Area Network and have full-featured Monitor & Control 
functions through a web interface. 

A description of the remote control protocol and asso-
ciated settings, conditions and thresholds tables are 
detailed in the Operations Manual. 

Maintenance 

Follow the instructions in the Operations Manual for 
proper maintenance of the controller. 

Download the operations manual and specification 
sheet for the controller from the Teledyne Paradise 
Datacom web site: http://www.paradisedata.com. 

PIN 

FUNCTION 

1 RS-485 

TX+ 

RS-232 out or RS-485 TX- 

RS-232 in or RS-485 RX- 

RS-485 RX+ 

5 Ground 

Service Request 1 (closed on fault) 

Service Request 2 (open on fault) 

Service Request Common (Form C Common) 

Termination (120 ohm) (connect to pin 4 to ter-
minate unit on end of bus) 

SERIAL PORT, MAIN (J4) CONNECTOR PIN-OUTS 

ETHERNET PORT (J9) CONNECTOR PIN-OUTS 

PIN 

FUNCTION 

PIN 

FUNCTION 

1 TX+  5 GND 

TX- 

RX- 

3 RX+  7 GND 

GND 

GND 