PS200
PORTABLE GAS MONITOR
MANUAL BUMP TEST OPTIONS
64171, Rev. 11/December 2019
6-1
6. MANUAL BUMP TEST OPTIONS
6.1. Bump Testing
A bump test verifies sensor response and alarm operation by exposing the monitor to a known con
-
centration of gas.
The monitor has 2 manual bump test options:
• QUICK bump test validates sensors respond to gas and alarms are working.
• FULL bump test checks the response of all sensors against set limits and alarms are working.
By default, both of these options are disabled.
A bump test kit (Part No. 64051) is available and contains test gas, a regulator, and Tygon® tubing.
6.2. Initiating a Manual Bump Test
If enabled, switch the monitor ON by pressing the L button.
During warm-up, the BUMP TEST confirmation screen appears, as shown in
. Press the R button to continue.
Figure 6-1: BUMP TEST Confirmation Screen
When warm-up is complete, the APPLY GAS screen appears, as shown in
WARNING: A QUICK BUMP TEST ONLY CHECKS THE OPERATION OF THE
AUDIBLE AND VISUAL ALARMS. IT DOES NOT VALIDATE SENSOR
ACCURACY OR RESPONSE TIME.
WHEN PERFORMING A BUMP TEST, THE TEST GAS CONCENTRATION
SHOULD BE HIGH ENOUGH TO TRIGGER THE MONITOR’S ALARMS. IF
ANY MONITOR FAILS A BUMP TEST, PERFORM A FULL CALIBRATION
BEFORE USING THAT MONITOR.
Содержание PS200 Series
Страница 10: ...64171 Rev 11 December 2019 x PS200 PORTABLE GAS MONITOR LIST OF TABLES This page is intentionally left blank ...
Страница 20: ...PS200 PORTABLE GAS MONITOR INTRODUCTION 64171 Rev 11 December 2019 2 4 This page is intentionally left blank ...
Страница 34: ...PS200 PORTABLE GAS MONITOR ALARMS 64171 Rev 11 December 2019 4 4 This page is intentionally left blank ...
Страница 54: ...PS200 PORTABLE GAS MONITOR ACCESSORIES 64171 Rev 11 December 2019 10 2 This page is intentionally left blank ...