PP007 Passive Probe 

12 

 

Certifications 

Teledyne LeCroy certifies compliance to the following standards as of the 
date of publication. See the EC Declaration of Conformity shipped with the 
product for current certifications. 

EC Declaration of Conformity - Safety 

The probe meets intent of EC Directive 2014/35/EU for Product Safety. 
Compliance was demonstrated to the following specifications as listed in the 
Official Journal of the European Communities: 
IEC/EN 61010-031:2015 Safety requirements for electrical equipment for 
measurement, control and laboratory use – Part 031: Safety requirements for 
handheld probe assemblies for electrical measurement and test. 

 

Measurement Category II (CAT II) refers to measurements performed 
on circuits directly connected to utilization points (socket outlets and 
similar) of the low-voltage mains installation. 

 

Pollution Degree 2, operating environment where normally only dry 

non-conductive pollution occurs. Conductivity caused by temporary 
condensation should be expected. 

Environmental Compliance 

E

ND

-O

F

-L

IFE 

H

ANDLING

 

The probe is marked with this symbol to indicate that it complies 
with the applicable European Union requirements to Directives 
2012/19/EU and 2013/56/EU on Waste Electrical and Electronic 
Equipment (WEEE) and Batteries. 
The probe is subject to disposal and recycling regulations that vary 

by country and region. Many countries prohibit the disposal of waste 
electronic equipment in standard waste receptacles. For more information 
about proper disposal and recycling of your Teledyne LeCroy product, please 
visit teledynelecroy.com/recycle. 

R

ESTRICTION OF 

H

AZARDOUS 

S

UBSTANCES 

(R

O

HS) 

The probe and accessories conform to the 2011/65/EU RoHS2 Directive. 

Содержание PP007

Страница 1: ...PP007 WR 1 PP007 WR 2 PP007 WS 1 PP007 WS 2 Operator s Manual PP007 Passive Probe...

Страница 2: ...rranty Teledyne Lecroy at its option will either repair or replace any assembly returned within its warranty period to the Customer Service Department or an authorized service center However this will...

Страница 3: ...erstood and met DOUBLE INSULATION PROTECTIVE EARTH TERMINAL Precautions To avoid personal injury or damage to property review and comply with the following safety precautions Use product only as speci...

Страница 4: ...s case or touching exposed connections may result in electric shock Use only within operational environment listed Use indoors only Do not use in wet or explosive atmospheres Keep product surfaces cle...

Страница 5: ...compensation network All accessories are interchangeable between all models Keep fingers behind the probe s finger guard during use Rated for indoor use only Do not operate where conductive pollutants...

Страница 6: ...Environment Temperature Operating 0o to 50o C Temperature Storage 40o to 71o C Altitude Operating up to 2000 m 6560 ft Humidity Operating 5 to 85 RH up to 30 C 5 to 65 RH 30 C to 40 C 5 to 45 RH abov...

Страница 7: ...Kit replaces the common standard accessories with Qty 2 each of 1 2 4 5 and 14 plus Qty 1 adjustment tool 3 PK702 Advanced Adapter Kit contains a large assortment of accessories Qty 1 each of 1 2 3 5...

Страница 8: ...PK007 005 Spring Tip 0 5 mm PK007 007 Insulating Cap PK007 008 IC Cap 0 5 mm pitch green PK007 009 IC Cap 0 65 mm pitch blue PK007 010 IC Cap 0 8 mm pitch gray PK007 011 IC Cap 1 0 mm pitch brown PK0...

Страница 9: ...18 19 20 PK007 017 Single Lead Adapter PK007 018 Dual Lead Adapter PK007 022 Adapter 2 mm plug PK007 023 Adapter 4 mm plug 21 22 23 PK007 019 Pico Hook PK007 020 Micro Clip Long PK007 021 Micro Clip S...

Страница 10: ...ator Clip 28 29 30 PK007 026 Ground Lead with mini clip PK007 027 Ground Lead 8 mm socket PK007 028 Ground Lead 2 mm plug 31 32 PK007 029 Ground Lead 4 mm plug PK007 030 High Frequency Compensated Gro...

Страница 11: ...ther maintenance and component replacement should be referred to qualified personnel Cleaning The outside of the probe should cleaned with a soft cloth dampened with either deionized distilled water o...

Страница 12: ...signed LF compensation is performed by connecting the input of the probe to a low frequency square wave such as the oscilloscope calibrator signal set to 1 kHz The compensation is adjusted by rotating...

Страница 13: ...r tip for their application needs To change the tip or replace it when damaged carefully grip the outer most portion and pull straight out along the axis of the probe using needle nose pliers Do not a...

Страница 14: ...cted to utilization points socket outlets and similar of the low voltage mains installation Pollution Degree 2 operating environment where normally only dry non conductive pollution occurs Conductivit...

Страница 15: ......

Страница 16: ...928597 00 Rev A July 2017...

Отзывы: