background image

TE

LE

D

Y

N

E

 R

D

 IN

S

TR

U

M

E

N

TS

P/N 95B-6134-00 (April 2018)

St

ep 3 B

 Connecting the P

ow

er/Comm Cable

St

ep 3 C

 Setting Up the Communications

1. 

Place the Pioneer on its transducer face on a so

ft sur

face. 

2. 

Remov

e the P

ow

er/Comm pr

ot

ectiv

e cap and lubricat

e the connect

or

.

3. 

Push the cable straight ont

o the P

ow

er/C

OMM connect

or ensuring the pins ar

e pr

operly 

aligned. While k

eeping a slight inwar

d pr

essur

e on the cable connect

or and ensuring that 

the connect

or is straight, thr

ead the locking sleev

e ont

o the r

eceptacle t

o complet

e the 

connection.

4. 

Attach the P

ow

er/Comm cable t

o the comput

er

’s serial communication por

t. Use an RS-422 

to RS-232 adapt

er if the DVL is configur

ed with por

t 1 as RS-422.

5. 

Connect the pow

er adapt

er cable t

o the DVL/P

ow

er/Comm cable pow

er connect

or by 

pushing it all the way in until it “

clicks”

. C10.7 t

o 36 VDC pow

er

. The pow

er supply 

should be able t

o sour

ce at least 4 Amps.

6. 

Place the Pioneer syst

em in wat

er (at least a few inches t

o cov

er the transducer face).

7. 

Establish communications with the Pioneer

.

St

ep 3 Communication and P

ow

er Setup - Detailed Instructions

St

ep 3 A

 Wiring the S

tandar

d P

ow

er/Comm Pigtail Cable

Wir

e the pigtail cable or use the P

ow

er/Comm T

est Cable.

To establish communications with the Pioneer

:

1. 

Connect and pow

er the syst

em as shown in S

teps 3A and 3B. 

2. 

Star

t the 

TRDI T

oolz 

so

ftwar

e (installed in S

tep 2). 

3. Select 

New Ser

ial Connection.

4. 

Ent

er the Pioneer

’s communication settings. 

 For 

Ser

ial

 comms select the C

OM P

or

t the cable connect

ed t

o and set 

the Baud Rat

e t

o 115200.

 

5. 

Click the 

Connect 

butt

on. Once connect

ed, the butt

on will change t

Disconnect.

6. 

Click inside the t

er

minal window and then click the 

Br

eak 

(      ) butt

on 

locat

ed at the bott

om lef

t o

f the t

er

minal window

. The wak

eup b

anner 

below will be display

ed.

 

Pioneer DVL 

 

Teledyne RD Instruments (c) 2015

 

All rights reserved.

 

Firmware Version: 57.xx

Refer t

o the Int

egration Guide for fur

ther infor

mation.

EAR-

Con

tr

olled 

Technology Subjec

t t

o R

estr

ic

tions C

on

tained on the C

ov

er P

age

.

1

1

1

To Serial Port

(COM1 or COM2)

DVL/Power/Comm Cable

73B-3004-005

RS

-232 or use

RS

-422 t

o RS

-232 A

dapt

er 

*

*

Pr

ior t

o each c

onnec

tion:  

Lubr

ica

te ma

ting sur

fac

es with 

3M Silic

one Spr

ay or equiv

alen

t. 

DO NO

T g

rease!

10.7 to  36 VDC (32 VDC typical)

4 AMP

Bucket of W

ater

Pioneer DVL

Power Adapter 

Cable

73B-6046-00

TRDI T

oolz

Отзывы: