background image

LSIB-1 Host Interfaces 

12 

 

 

LSIB-OM-E Rev C 

Laptop or PC Application, Linux 
Driver Installation, and Libraries 

Instead of using the installation CD provided with the 
Interface, the software can also be accessed from the 

Teledyne LeCroy website at teledynelecroy.com. 

Overview 

The software for LSIB Linux consists of the following 

components and their associated include and make files. 

 

The kernel driver. 

 

A user library named 

lecroylsiblib

 

Three demo programs named 

LSIBPerformance

LSIBexportsample

, and 

LSIBcontrolsample

These are all supplied as source files, written in C/C++, 
and packaged in a bzip2 compressed tar file named  

LSIB -xxxxxx.tz2

NOTE

: You need to compile the source files and install 

them on your system. 

Requirements 

 

The LSIB Linux driver requires the use of MTRRs 
(Memory Type Range Registers) to map the memory 

used for communications. This requires kernel 
version 2.6.20 or greater. 

 

The use of the MTRRs also require the CPU be a 

64-

bit AMD

 or an 

Intel

 processor running a 

64-bit 

version of Linux

 

The gcc compilers. 

 

The kernel sources. These can be obtained by 

issuing the following Redhat Linux command: 

# yum install kernel-devel Kernel-headers

 

Содержание LSIB-1

Страница 1: ...Operator s Manual LSIB 1 Host Interfaces...

Страница 2: ......

Страница 3: ...LSIB 1 Host Interfaces Operator s Manual January 2013...

Страница 4: ...ly prohibited However clients are encouraged to distribute and duplicate Teledyne LeCroy documentation for their own internal educational purposes LSIB 1 and Teledyne LeCroy are registered trademarks...

Страница 5: ...on Unpacking and Installation 5 Description 5 Unpacking 5 Installation 6 LSIB HOSTBOARD Description Unpacking and Installation 8 Description 8 Unpacking 8 Installation 9 Powering Sequence 10 Laptop or...

Страница 6: ...xport Sample 21 Performance Demo Application 26 Compiling Custom Code 32 Specifications 33 Certifications 33 EC Declaration of Conformity EMC 33 EC Declaration of Conformity Low Voltage 33 EC Declarat...

Страница 7: ...have been shipped to you Contact your nearest Teledyne LeCroy customer service center or national distributor if anything is missing or damaged You must contact us immediately for a replacement If yo...

Страница 8: ...The package should contain your hardware based on what you ordered LSIB HOSTCARD for laptops or LSIB HOSTBOARD for PCs It also contains the cable you ordered either 3M or 7M Your configuration should...

Страница 9: ...a bracket for proper 4x motherboard installation LSIB HOSTCARD or LSIB HOSTBOARD comes with your choice of a 7M pictured below or 3M x4 connection cable Attach the cable to LSIB HOSTCARD or LSIB HOST...

Страница 10: ...nnectors on either end of the cables are identical and allow for upstream and downstream transfers System Requirements Operating System Windows 7 x86 and Windows 7 X64 Windows Vista x86 Windows Vista...

Страница 11: ...connectivity to oscilloscopes configured with the LSIB 1 option Unpacking 1 If the carton is damaged upon receipt Request the carrier s agent be present when unpacking and inspecting the contents If...

Страница 12: ...eturn shipment of the equipment 5 Remove LSIB HOSTCARD from the anti static bag Installation 1 Shut down the host laptop into which you are installing the card 2 Remove the plastic filler plate if nec...

Страница 13: ...eable and allow for upstream and downstream transfers 4 Push the cable into the ExpressCard slot until it locks into place 5 Attach the other end of the cable to the oscilloscope NOTE Reverse these st...

Страница 14: ...s If the contents appear damaged contact your local Teledyne LeCroy Corporation representative to obtain a Return Materials Authorization RMA number and further shipping instructions for any repair an...

Страница 15: ...manufacturers may limit the bandwidth to x1 speeds when up plugging the Target Cable Adapter into an x8 or x16 slot Be sure to check with the motherboard manufacturer for up plugging details A PCIe x...

Страница 16: ...ware Be sure to click Cancel if prompted to install drivers Install the drivers using the CD provided with the Interface Do not disconnect cables while your Laptop PC and the instrument are powering u...

Страница 17: ...ed by default and should be left this way The Desktop Shortcut check box is unchecked by default Include or exclude the shortcut as desired One of the installation prompts has check boxes checked by d...

Страница 18: ...e LSIBexportsample and LSIBcontrolsample These are all supplied as source files written in C C and packaged in a bzip2 compressed tar file named LSIB xxxxxx tz2 NOTE You need to compile the source fil...

Страница 19: ...IB_xxxxxx LSIB make all 3 Install the driver make install 4 Start the driver make startdriver NOTE At this point you may need to shutdown the oscilloscope and the host computer laptop If so be sure to...

Страница 20: ...ation Include Directory containing the LSIB include files Lecroylsib Directory containing the LSIB library files Lsibcontrolsample Application demonstrating LSIB control functionality Lsibexportsample...

Страница 21: ...onnection allowing you to control the oscilloscope using remote commands Currently Scope Explorer is not supported Export demonstrates the transfer of data from the oscilloscope to the host PC and con...

Страница 22: ...following locations Windows Start All Programs Teledyne LeCroy XStream LSIB folder Linux directory_path LSIB_xxxxxx LSIB NOTE directory_path refers to the location where you unzipped the tar archive U...

Страница 23: ...Operator s Manual LSIB OM E Rev C 17 LINUX On The Oscilloscope 2 Go to Utilities Utilities Setup On the Remote tab click the LSIB button...

Страница 24: ...LSIB 1 Host Interfaces 18 LSIB OM E Rev C On Your Laptop PC 3 Verify the remote control interface on the host Laptop PC shows the LSIB is connected WINDOWS LINUX...

Страница 25: ...OM E Rev C 19 4 With the connection made between the host Laptop PC and the oscilloscope use the remote control interface to verify connectivity Type IDN and press enter You should see the following...

Страница 26: ...face Please refer to the Remote Control and Automation manuals for more information Enter a remote command to test the connection is operating correctly Some examples of remote control commands includ...

Страница 27: ...t sample allows for transmitting waveforms in the TRC format to the host Laptop PC Launch the sample from the following locations Windows Start All Programs Teledyne LeCroy XStream LSIB folder Linux d...

Страница 28: ...22 LSIB OM E Rev C Use the Export Sample by completing the following steps On Your Laptop PC 1 Confirm the remote control interface on the host Laptop PC indicates that it s Waiting for Connection as...

Страница 29: ...Waveform 2 Click the LSIB Export tab on the lower part of the screen and select the appropriate data stream for your performance test Data Stream 1 is selected in the following example On Your Laptop...

Страница 30: ...LSIB 1 Host Interfaces 24 LSIB OM E Rev C LINUX...

Страница 31: ...Transmitting Waveforms When the s key is pressed the application fetches a waveform from the oscilloscope prints some of the header on the console converts the data into the TRC format and saves it in...

Страница 32: ...mance Demo Application is to demonstrate the transfer rate of waveforms sent using the LSIB Export functionality Launch the Demo Application from the following locations Windows Start All Programs Tel...

Страница 33: ...Manual LSIB OM E Rev C 27 Run the Performance Demos by completing the following steps On Your Laptop PC 1 Confirm that after launching the Performance Demo Application the following screen is shown WI...

Страница 34: ...data stream you want to use for porting the information from the oscilloscope by selecting 1 2 3 or 4 The application measures data throughput and transfers waveforms from the oscilloscope and the hos...

Страница 35: ...Operator s Manual LSIB OM E Rev C 29 LINUX...

Страница 36: ...part of the screen and select the data stream that was used for your performance test Data Stream 1 is selected in the following example NOTE You should see the word connected to the right of the sel...

Страница 37: ...Operator s Manual LSIB OM E Rev C 31 LINUX...

Страница 38: ...B ControlSample or LSIB ExportSample folders Open sln files using Visual Studio Code adjustments may be necessary if using a compiler other than Visual Studio s Some considerations Make code change ad...

Страница 39: ...ng specifications as listed in the Official Journal of the European Communities EN 61326 1 2006 EN 61326 2 1 2006 EMC requirements for electrical equipment for measurement control and laboratory use E...

Страница 40: ...nd of Life Handling This oscilloscope accessory is subject to disposal and recycling regulations that vary by country and region Many countries prohibit the disposal of waste electronic equipment in s...

Страница 41: ...ications indirect teledynelecroy com teledynelecroy com europe Protocol Analyzers Ph 44 12 765 03971 Singapore Oscillosocpes Teledyne LeCroy Singapore Pte Ltd Blk 750C Chai Chee Road 02 08 Technopark...

Страница 42: ...LSIB 1 Host Interfaces 36 LSIB OM E Rev C...

Страница 43: ......

Страница 44: ......

Отзывы: