Linea CL Series Camera
Appendix B: ASCII Commands
•
77
SBR: Set Baud Rate
Display
Name
Set Baud Rate
Mnemonic
SBR
Argument(s) Baud rate
9600
57600
115200
230400*
460800*
921600*
Description
Set baud rate
Notes
•
Send command and then change speed of HyperTerminal
•
*A PX4 or equivalent frame grabber is required in order to achieve
these baud rates.
SBV: Set Binning Vertical
Display
Name
Set Binning Vertical
Mnemonic
SBV
Argument(s)
1.
Single pixel
2.
Binning of 2 pixels
Description
Set vertical binning
SEM: Set Exposure Mode
Display
Name
Set Exposure Mode
Mnemonic
SEM
Argument(s) Mode
0.
Internal (“Timed”)
1.
External (“PulseWidth”)
Description
Set exposure time mode
Notes
•
In internal mode the exposure time is controlled by the SET command
•
In external mode the sensor is exposed while CC1 signal is high
•
External mode is only available when the trigger mode is also
external (STM 1)
•
SEM 1 overrides internally generated independent exposure times
•
When CC1 signal falls line is read