background image

Digital AVC Instruction Manual

 

EAR99 Technology Subject to Restrictions Contained on the Cover Page

 

Page 17 of 17 

5. 

Outline Drawings 

The following section(s) show the outline dimensions for the HPM 4/5/6. 

  

Содержание HPM 4

Страница 1: ...m I S O 9 0 0 1 C E R T I F I E D INSTRUCTION MANUAL Use and Disclosure of Data Information contained herein is classified as EAR99 under the U S Export Administration Regulations Export reexport or diversion contrary to U S law is prohibited ...

Страница 2: ...n of Symbols and Messages used in this manual WARNING indicates a hazardous situation which if not avoided could result in death or serious injury Do not proceed beyond a WARNING notice until the indicated conditions are fully understood CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury Do not proceed beyond a CAUTION notice until the indicated c...

Страница 3: ...Installation 9 BATTERY INSTALLATION REPLACEMENT 10 2 3 1 Battery Life Notes 10 3 VACUUM GAUGE OPERATION 11 FRONT PANEL 11 3 1 1 Pressure Graph 11 3 1 2 Battery Level 11 3 1 3 Tube Type 12 3 1 4 Current Pressure 12 3 1 5 Pressure Units 12 3 1 6 Power Enter Key 12 3 1 7 DV Select UP Key 12 3 1 8 Units Select Down Key 12 ELECTRICAL CONNECTOR 12 QUICK START 13 USER OPTIONS AND ADJUSTMENTS 13 3 4 1 Aut...

Страница 4: ...Digital AVC Instruction Manual EAR99 Technology Subject to Restrictions Contained on the Cover Page Page 4 of 17 4 WARRANTY AND REPAIR 16 WARRANTY REPAIR POLICY 16 RETURN POLICY 16 5 OUTLINE DRAWINGS 17 ...

Страница 5: ...e are no operator serviceable parts or adjustments inside the product CAUTION If this equipment is used in a manner other than that specified the protection provided by the equipment may be impaired Features The HPM 4 5 6 is a battery operated hand held vacuum gauge that supports the Teledyne Hastings DV 4 DV 5 and DV 6 series vacuum gauge tubes It is designed for portability and ease of use in ap...

Страница 6: ...r DV 6 1 1000 mTorr 15 of Reading 3 mTorr Operating Temperature Range With alkaline battery standard 18 to 55 C With lithium battery standard 20 to 60 C Externally powered 20 to 70 C Storage Temperature without battery 20 to 70 C Input Voltage 5 5 9 5 VDC 9V Battery Battery Life with included battery 30 hours Outline Dimensions in inches mm 3 35 by 5 66 by 1 40 85 by 144 by 36 Weight Approx 0 7 lb...

Страница 7: ...o the sensor s thermocouple 1 3 2 Calibration Reference Tubes Reference Tubes employ the same metal thermopiles used in all THI Vacuum Gauge Tubes The thermopile is sealed in a glass capsule that has been evacuated baked outgassed and aged to ensure long term stability The sealed capsule is housed in a rugged metal shell to provide a trouble free assembly The reference gauge tube is calibrated to ...

Страница 8: ...VCRTM 55 103 DB 18 Ref Tube DV 5 Gauge Tubes 1000 mTorr Range 55 38 DV 6M 1 8 MNPT Yellow Base 55 38R DV 6R 1 8 MNPT Ruggedized 55 38RS DV 6 1 8 MNPT Ruggedized RoHS 55 38S DV 6S 1 8 MNPT Ruggedized Vibration 55 139 DV 20 Glass 55 251 DV 6 KF 16 KF 16TM 55 267 DV 6 KF 25 KF 25TM 55 283 DV 6 VCR VCRTM 55 38R CF DV 6R CF Mini ConflatTM 55 66 DV 36 1 8 MNPT 316SS 55 104 DB 20 Ref Tube DV 6 ...

Страница 9: ...ber boot easier to reach the cable lock a Open the stand and push the bottom portion of the instrument out of the boot b Pull the rest of the instrument out of the boot c Be careful not to bend the cable connector plug 2 Pull the cable through the boot opening until you can easily grasp the Connector Plug 3 Twist the coupling ring counterclockwise about 120 degrees until you feel it unlock and hit...

Страница 10: ...and wires into the compartment 6 Reinstall the battery compartment cover by pressing down on the battery with the cover and sliding the cover until it snaps into position 7 See 2 2 2 to put the cable back on and re insert into the boot 2 3 1 Battery Life Notes Battery life specifications are given at 20 C If the HPM 4 5 6 is operated for a significant time at temperatures much lower than this batt...

Страница 11: ...ation in other modes 3 1 1 Pressure Graph This shows a general indication of current pressure within the measurable range If the pressure is higher than the measurable range the graph flashes and displays an arrow on the right end If the pressure is lower than the measurable range the graph flashes and displays an arrow on the left end 3 1 2 Battery Level Displays battery life charge The battery s...

Страница 12: ...en held longer than 3 seconds during power on temporarily disables Auto Shutoff Acts as an Enter key in adjustment modes 3 1 7 DV Select UP Key Changes the gauge tube type and functions as the up key in adjustment modes 3 1 8 Units Select Down Key Changes the pressure units and functions as the down key in adjustment modes Electrical Connector Teledyne Hastings vacuum gauge tubes interface with th...

Страница 13: ...ANGE which indicates the vacuum gauge tube is either outside the measurable range or not connected iii Flashing 000 UNDER RANGE which indicates the vacuum gauge tube is at a pressure less than the measurable range 6 Press the power button to turn the unit off This will help prolong battery life If tube type and or conversion units have been changed the instrument will use these selections the next...

Страница 14: ...while flashing the tube type in the upper right hand corner 3 5 3 Select Tube Type and Units Press TUBE SELECT or UNITS SELECT until the correct gauge tube is displayed Press POWER to accept the tube type selection The LCD will flash Select Units while flashing the Pressure Units in the lower right hand corner Press TUBE SELECT or UNITS SELECT until the desired pressure units are displayed Press P...

Страница 15: ...t to the right shows the amplified output from the gauge tube as the ambient temperature changes from 25 C to 77 C The instruments are initially adjusted at an ambient temperature of approximately 22 C The dominant effect is the change in the zero pressure output of the tube This effect can be corrected by adjusting the low pressure reading at the operating ambient temperature The mid range of the...

Страница 16: ...nty repair must have been issued a Return Material Authorization RMA form RMA Forms may be obtained from the Information section of the Hastings Instruments website http www teledyne hi com inforeq htm WARNING Contaminated parts can be detrimental to health and environment Ensure instruments are free of hazardous contamination prior to shipment Company contact information TELEDYNE HASTINGS INSTRUM...

Страница 17: ...Digital AVC Instruction Manual EAR99 Technology Subject to Restrictions Contained on the Cover Page Page 17 of 17 5 Outline Drawings The following section s show the outline dimensions for the HPM 4 5 6 ...

Отзывы: