Command
SEQuence:ELEM[n]:JUMPEvent
Description
This command sets or returns the jump event type for the selected
element ‘n’.
Group
Sequence
Syntax
SEQuence:ELEM[n]:JUMPEvent {NONE|MANual|TIMer|EXTernal}
SEQuence:ELEM[n]:JUMPEvent?
Related Commands
SEQuence:ELEM[n]:JUMPTOEntry
SEQuence:ELEM[n]:JUMPTOMode
AWGControl:JUMPMode
Arguments
<jump_event>::= {NONE|MANual|TIMer|EXTernal}
NONE: the jump event is disabled.
MANual: the jump event is sent via software or by pressing the front
panel button.
TIMer: the jump event is generated by an internal timer.
EXTernal: the jump event comes from the external BNC connector
Returns
< jump_event >::= {NONE|MANual|TIMer|EXTernal}
Example
SEQuence:ELEM1: JUMPEvent MANual
It sets the jump event for first element of the sequence to manual
SEQuence:ELEM1:JUMPEvent?
Might returns MANual.
Table 154: SEQuence:ELEM[n]:JUMPEvent
Command
SEQuence:ELEM[n]:JUMPTOEntry
Description
This command sets or returns the target entry index
for the “Jump
To” command for the selected element ‘n’ of the sequencer.
After generating the waveform(s) specified in a sequence element,
the
sequencer jumps to the entry specified as the “Jump To” target
index after the event occurs. This is a conditional jump.
Note:
this will take effect only when SEQuence:ELEM[n]:JUMPTOMode is
set to ITEM
Group
Sequence
Syntax
SEQuence:ELEM[n]:JUMPTOEntry
{MINimum|MAXimum|DEFault|<value>}