Programming Manual
–
T3AWG3K-C Series Arbitrary Waveform Generator
True-Arb Operating Mode
104
MAXimum sets or queries the maximum amplitude level.
DEFault sets the default amplitude level (2V).
Returns
<Volts>::=<NRf>
Example
SEQuence:ELEM3:AMPlitude2 4
Sets the voltage amplitude of the channel 2 for sequencer element
3 to 4.
SEQuence:ELEM3:AMPlitude2?
Might returns 4.
Table 140: SEQuence:ELEM[n]:AMPlitude[m]
Command
SEQuence:ELEM[n]:OFFset[m]
Description
Sets or returns the voltage offset for the element “n” of the channel
“m”
Group
Sequence
Syntax
SEQuence:ELEM[n]:OFFset[m] {MINimum|MAXimum|DEFault|
<Volts>}
SEQuence:ELEM[n]:OFFset[m]? [{MINimum|MAXimum}]
Related Commands
SEQuence:ELEM[n]:AMPlitude[m]
Arguments
The value of n indicates the sequence element number.
The value of m is the channel number.
<Volts>::=<NRf> sets the offset level expressed in Volt.
MINimum sets or queries the minimum offset level.
MAXimum sets or queries the maximum offset level.
DEFault sets the default offset level (0V).
Returns
<Volts>::=<NRf>
Example
SEQuence:ELEM5:OFFset2 1.2
Sets the offset of the channel 2 for sequencer element 5 to 1.2 V
SEQuence:ELEM5:OFFset2? MAXimum
Might returns 2.5.
Table 141: SEQuence:ELEM[n]:OFFset[m]
Command
SEQuence:ELEM[n]:VOLTage:HIGH[m]
Description
This command sets or returns the high voltage level of the waveform
for the element “n” of the channel “m”.
Group
Sequence
Syntax
SEQuence:ELEM[n]:VOLTage:HIGH[m] {MINimum|MAXimum|
DEFault|<Volts>}