Teledyne 2240 Скачать руководство пользователя страница 5

Page 9 of 26 

M2240

 R0 

2. 

2240

 Functions and Features  

 
General Features  

The 

2240

 is designed as three section unit housed in a 

tough ABS carrying case with all the necessary 
accessories. The principle sections are: 

 

Controller – Containing the user interface, battery, and 
external electrical interfaces. (Serial and analog). 

 

Wand Assembly – extends the operator’s reach by 24 
inches,

 

making operation highly flexible.

 

 

Sensor Module – Containing the sensor element and 
sensor-specific electronics. Easily mounted on either the 
Controller or Wand Assembly.  

 

Electrical Features

 

 

Power provided by either the internal battery or through an 
optional 

Teledyne

 external power supply. 

 

Automatic self-test, activated on start-up, to confirm 
proper operation. 

 

Serial Interface: 9 pin Sub-D connector in RS-232 
configuration transmitting ASCII data in an 8 bit stream 
with no parity and 1 stop bit. 

 

Analog Interface: 0-5 V and 4-20 mA. (Reference Figure 
3). The analog output produces a signal proportional to the 
amount of hydrogen in air, an indication of Warm-Up 
Mode, or an indication of Error Mode as determined by the 
operator-selected format. (See section 5) 

   

Operator Interface Features 

 

LCD: provides readable (alphanumeric) information on 
current readings and settings.. 

 

Tri-colored (green/yellow/red) LED: indicates instrument 
status and changes in hydrogen concentration. 

 

Audible alarm: Operator programmable level provides a 
single beep each time a new peak hydrogen concentration 
is detected and provides a continuous series of beeps if the 
programmable Alarm setting is exceeded.  

Page 10 of 26 

M2240

 R0 

3. 

Component

 Identification 

 

Connector

 

Handle

 

Sensor Module

 

containing the Wide 

Range Sensor® 

LED Display

Mode 

Button

 

LCD Display

Enter Button

Power Button

 

Scroll 

Buttons

 

LED Display

Controller

Receiver

Sensor 

Module, 

shown 

attached after 

removing 

from the 

Controller 

Battery Door

Release Tab

Sensor 

Release Tab

Battery Door

Wand 

Assembly

 

Coiled Cable

 

Figure 2 - 

2240

 Controller and Wand Assy. 

Содержание 2240

Страница 1: ...ORTANT NOTICES READ THIS INSTRUCTION MANUAL BEFORE OPERATING OR SERVICING YOUR 2240 HYDROGEN SPECIFIC SENSING INSTRUMENT 1 HYDROGEN IS FLAMMABLE AT 4 IN AIR 2 BEWARE OF THE DANGER OF APPROACHING THE FLAMMABLE LIMIT OF HYDROGEN IN AIR TAKE 2240 INDICATIONS SERIOUSLY AND BE PREPARED TO TAKE ACTION TO ELIMINATE THE DANGER THERE IS A HIGH PROBABILITY OF HAZARD TO PUBLIC AND PERSONAL SAFETY IMMEDIATELY...

Страница 2: ... Teledyne s sole obligation under this warranty is to either i repair the Product ii replace the Product or iii issue a credit for the purchase price for such Product the particular remedy to be determined by Teledyne on a case by case basis Limitation of Warranty THE ABOVE IS A LIMITED WARRANTY AS IT IS THE ONLY WARRANTY MADE BY TELEDYNE TELEDYNE MAKES NO OTHER WARRANTY EXPRESS OR IMPLIED AND EXP...

Страница 3: ... a variable resistor in the presence of hydrogen The change in resistance is used to generate a signal that is proportional to the hydrogen concentration This device is used to sense hydrogen from 10 000 ppm to 100 The 2240 interprets the signals from both devices and displays an approximate hydrogen concentration to the operator NOTE The indicated concentration is an approximate value and should ...

Страница 4: ...y Life 6 hrs continuous use Atmospheric Pressure Influence As the 2240 is calibrated at standard sea level conditions hydrogen readings must be corrected for altitude To compensate for altitude variations multiply the instrument reading by the correction factor indicated in Figure 1 Example At an altitude of 800 m there is a correction factor of 1 10 A hydrogen reading of 1 5 will be corrected for...

Страница 5: ...erface 0 5 V and 4 20 mA Reference Figure 3 The analog output produces a signal proportional to the amount of hydrogen in air an indication of Warm Up Mode or an indication of Error Mode as determined by the operator selected format See section 5 Operator Interface Features LCD provides readable alphanumeric information on current readings and settings Tri colored green yellow red LED indicates in...

Страница 6: ...he Controller To attach the Sensor Module to the Wand Assembly Verify that power is OFF See section 5 Remove the Sensor Module from the Controller by pressing and holding down the release tab located on the back of the controller body The Sensor Module will unlatch Gently pull the Sensor Module away from the Controller body Position the Sensor Module above the Wand Assembly such that the release t...

Страница 7: ... resetting the unit Modes of Operation Initialization Mode A warm up self analysis mode that occurs automatically after power is turned on It lasts approximately five minutes The LCD displays a countdown to completion of the Initialization Mode Note the LCD displays Warm up and the LED is yellow indicating a non operating state During this time the system brings the Wide Range Sensor to operating ...

Страница 8: ... non operating state Turn off the system and verify that the Sensor Module and Wand Assembly if used are properly connected and firmly seated Check that the system is receiving sufficient power Ensure that the Battery is properly installed into the Controller Allow Batteries that have been in an extreme temperature to warm or cool to within 10 to 45 degrees C If the instrument continues to fail to...

Страница 9: ...ress the Mode button to select the digit to change Press the Enter key to set the displayed number into memory and return to the Configuration Mode 0 5 Volt Config abbreviation for 0 to 5 V Analog Output Configuration Mode Press the Enter button when 0 5 Volt Config is displayed The default setting of 0 5 Volt is displayed Press the Scroll buttons to view the available formats When the desired for...

Страница 10: ...0 hydrogen and 2 5 V 2 hydrogen For example using the 4 20 mA Analog Output the operator chooses 20 mA to indicate 10 hydrogen in air This results in 20 mA 10 hydrogen 4 mA 0 hydrogen and 12 mA 5 hydrogen Use the Scroll buttons to increase or decrease the percent value Use the Mode button to change the digit affected by the scroll buttons Press the Enter key to set the displayed number into memory...

Страница 11: ...is rising in an enclosed building where there typically is a layer of warmer air near the ceiling the hot air near the ceiling will have a lower density and may act to retard the hydrogen from continuing to rise as rapidly in lower layers of air Thus sensing hydrogen near ceiling areas with high temperatures present may not be as effective Low temperatures can also affect the behavior of hydrogen ...

Страница 12: ...e DC output plug into the socket on the Battery Charger Plug the power cord into an appropriate AC outlet The charging status lamp s will flash yellow then turn off Plug the battery or two batteries with optional Dual Bay Battery Charger into the pocket of the Battery Charger Make sure the battery is oriented properly and firmly seated down onto the connector blades batteries installed backwards w...

Страница 13: ...a battery that is outside the temperature range of 10 to 45 C The yellow lamp will illuminate and remain illuminated as long as the battery temperature is outside this range An error indication flashing red light will be given if the battery terminals are shorted or if the battery fails to properly take a charge In Case of a Problem If the Battery Charger does not function as expected check the fo...

Отзывы: