Страница 1: ...WaveRunner 8000 R Oscilloscopes Getting Started Guide ...

Страница 2: ... distribute Teledyne LeCroy documentation for internal educational purposes Teledyne LeCroy is a trademark of Teledyne LeCroy Inc Other product or brand names are trademarks or requested trademarks of their respective holders Information in this publication supersedes all earlier versions Specifications are subject to change without notice 930948 00 Rev A March 2019 700 Chestnut Ridge Road Chestnu...

Страница 3: ...scilloscopes See the WaveRunner 8000 Operator s Manual for information on the operational features of the WaveRunner 8000 R many of which can be controlled remotely using either traditional IEEE 488 2 commands or Windows COM Automation Both manuals can be downloaded from the Oscilloscope Manuals page on our website at teledynelecroy com support techlib Contents Introducing WaveRunner 8000 R 2 Key ...

Страница 4: ...aveRunner 8000 s analysis capability is available including an array of serial protocol analysis packages and application specific packages The WaveRunner 8000 R models are fully software compatible with their WaveRunner 8000 counterparts Development can be conducted with the assistance of the front panel and display of the WaveRunner 8000 then seamlessly transitioned to automated testing A variet...

Страница 5: ...ing of that input Refer to the markings next to the BNC terminals for maximum allowed values Use only within operational environment listed Do not use in wet or explosive environments Use indoors only Keep product surfaces clean and dry Do not block the cooling vents Leave a minimum six inch 15 cm gap between the instrument and the nearest object Keep the underside clear of papers and other object...

Страница 6: ...ope OVERVIEW A A Power On Standby Switch B Remote Status Indicator C Analog Inputs C1 C4 D External Trigger Input E USB 2 0 Port F Auxilliary AUX Output G Calibration Output Terminal H LBUS Port reserved I Ground Terminal B C D E F G H I ...

Страница 7: ...illoscope A AC Power Inlet B USBTMC Port C External Reference Clock Input REF In and Output REF Out D Removable Hard Drive OVERVIEW E USB 2 0 Ports 2 F USB 3 1 Gen1 Ports 2 G DisplayPort Video Output H VGA Video Output I Ethernet Ports 2 A B C D E F G H I ...

Страница 8: ...w that do not revert to the factory defaults when restarted as it is critical to know what the setting is in order to connect The factory default setting is LXI VXI11 but the instrument will reboot with whatever setting was last made We recommend that the remote control setting and the device address be set locally at installation prior to rackmounting and that it not be changed over a remote conn...

Страница 9: ... dialog The Remote dialog will show any dynamic IP address pulled BASICS 1 Install WaveStudio and NI VISA on the PC Open any firewalls between the PC and the oscilloscope to TCP IP communications on port 111 2 Power on the WaveRunner 8000 R and connect to a network access point using a standard Ethernet cable It is helpful if the network is served by a DHCP server as this will allow you to test ad...

Страница 10: ...rver be sure it is known to the DNS server by this name The WaveRunner 8000 R is preset to pull a dynamic IP address once it is connected to a network served by a DHCP server but this address will be replaced whenever the oscilloscope is restarted after being powered down We recommend setting a static IP address for remote control especially if you will be using automated programs for control Remo...

Страница 11: ...WaveRunner 8000 R can be controlled over a coaxial cable or a straight ENET cable capable of directional switching as most modern cables are In this case choose Control From TCPIP VICP and follow all other requirements for that method Be sure to set a static IP address on the WaveRunner 8000 R unless you are running a DHCP server on the controller as otherwise there will be no way to manage dynami...

Страница 12: ...igned to fit standard 19 inch rack cabinets per EIA ECA 310 E Weight of instrument 7 5 kg 16 5 lbs Weight of instrument rackmount installed 7 65 kg 16 8 lbs Width rackmount installed 484 mm 19 0 in Depth rackmount installed 445 mm 17 5 in Installation Instructions 1 Position the left bracket so that the screw holes align with the two holes on the side of the oscilloscope The mounting ears should b...

Страница 13: ...WaveRunner 8000 R Getting Started Guidel 11 BASICS ...

Страница 14: ...and pointing device to the WaveRunner 8000 R for this procedure 1 Go to the URL above and download XStreamDsoInstaller64 exe onto a portable USB drive If you don t yet have a user account on our website create one now 2 Close the oscilloscope XStreamDSO application by choosing File Exit 3 With the WaveRunner 8000 R powered on insert the drive containing the installer into one of the oscilloscope s...

Страница 15: ... padding to avoid damage in transit 5 Mark the outside of the box with the shipping address Add ATTN RMA code assigned by Teledyne LeCroy FRAGILE 6 If returning a product to a different country Mark the shipment Return of US manufactured goods for warranty repair recalibration List any cost of service in the Value column and the original purchase price For insurance purposes only Be very specific ...

Страница 16: ...000 4 11 2004 Mains Dips and Interruptions 0 1 cycle 70 25 cycles 0 250 cycles 4 6 1 To ensure compliance with all applicable EMC standards use high quality shielded interface cables 2 Emissions which exceed the levels required by this standard may occur when the instrument is connected to a test object 3 This product is intended for use in nonresidential areas only Use in residential areas may ca...

Страница 17: ... VOLTAGE The oscilloscope meets intent of EC Directive 2014 35 EU for Product Safety Compliance was demonstrated to the following specifications as listed in the Official Journal of the European Communities EN 61010 1 2010 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requirements EN 61010 2 030 2010 Safety requirements for electrical equipm...

Страница 18: ...must first examine the product and find that it is defective due to workmanship or materials and not due to misuse neglect accident or abnormal conditions or operation Teledyne LeCroy shall not be responsible for any defect damage or failure caused by any of the following a attempted repairs or installations by personnel other than Teledyne LeCroy representatives b improper connection to incompati...

Страница 19: ...WaveRunner 8000 R Getting Started Guidel 17 ...