Calibrating TF-HDMI-3.3V
For all channels using the TF-HDMI-3.3V adapter, calibrate out the TF-HDMI-3.3V offset on each lane to be tested prior to
running the QualiPHY tests.
As long as the test setup remains the same, this calibration should be good for all
acquisitions made within the same software session.
1.
With no signal attached, turn on all input channels using TF-HDMI-3.3V to display a DC baseline trace(s).
2.
Turn on all channels using the TF-HDMI-3.3V adapter.
3.
Turn on the oscilloscope’s MEAN voltage measurement on all displayed channels.
4.
Insert the supplied adjustment tool into the Terminator Adjust port on the TF-HDMI-3.3V adapter and turn it until
the measured MEAN is 3.3 V ±10 mV.
5.
Repeat Step 4 such that all channels measure the same voltage and all traces are aligned.
© 2021 Teledyne LeCroy, Inc. All rights reserved.
Teledyne LeCroy is a trademark of Teledyne LeCroy, Inc., Inc. Other product or brand names are trademarks or requested
trademarks of their respective holders. Information in this publication supersedes all earlier versions. Specifications are
subject to change without notice.
Unless otherwise specified, all materials and processes are compliant with RoHS Directive 2011/65/EU in its
entirety, inclusive of any further amendments or modifications of said Directive.
May be subject to disposal and recycling regulations. For more information, visit teledynelecroy.com/recycle.
700 Chestnut Ridge Road
Chestnut Ridge, NY 10977–6499
Tel: (845) 578 6020, Fax: (845) 578 5985
teledynelecroy.com
tf-hdmi-3.3v-instructions.pdf
June, 2021