![Teledyne Lecroy Summit T416 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/teledyne-lecroy/summit-t416/summit-t416_quick-start_1080999002.webp)
Rear Panel Description
The rear panel of the Analyzer has:
Wide-range AC Connector Module
•
Power socket
•
Enclosed 5.0 A 250 V fuse
Sync In and Sync Out
: Allows multiple Teledyne LeCroy analyzers to send
synchronization and control messages to one another.
Warning!
For continued protection against fire, replace fuse
only with the type and rating specified above.
Front Panel Description
The Analyzer has the following features on the front:
[1] Power Switch
(black): 1 = On and 0 = Off.
[2] LCD Menus
: Allows you to configure Summit T416 and view status.
[3] Navigation Buttons
: Navigate through the LCD menu.
[4] Speed LEDs
: Indicate speed setting the analyzer is using for each
traffic direction.
[5] Upstream [15:0] LEDs
: Lane activity for upstream lanes. OFF for
electrical idle, orange for activity with errors detected, green for normal
operation.
[6] Upstream [15:8] and Upstream [7:0] connectors
: Connection to the
probe for the capture of upstream direction of the link.
[7] Downstream [15:0] LEDs
: Lane activity for downstream lanes. OFF
for electrical idle, orange for activity with errors detected, green for
normal operation.
[8] Downstream [15:8] and Downstream [7:0] connectors
: Connection
to the probe for the capture of downstream direction of the link.
[9] Trigger IN and Out
: Provide external trigger capabilities. You can
configure Summit T416 to trigger external equipment using Trigger Out.
You can use Trigger In to trigger the Analyzer from another device.
[10] USB 3.0 Type B Host Machine Connector
: To connect the Analyzer to
the host machine using a USB connection.
[11] Ethernet Port
: 1 GIGE Connectivity allows connection to the analyzer
through an Ethernet network.
[12] Status LED
: Displays the connection status of the link.
Red -
Error condition. Try using the PCIe Protocol Analysis
application to clear the error. Please contact the factory
if this does not work.
Green -
Configuring system.
Blue -
Unit ready/connected.
[13] Trigger LED
: Lights when Summit T416 triggers on an event.
[14] DS Ref Clk In:
Downstream Reference Clock Input SMA.
[15] US Ref Clk In:
Upstream Reference Clock Input SMA.
LCD Menus
The Summit T416 has a front LCD panel that displays the computer name that
is currently connected to the system, the unit serial number, and the current
network configuration. If no computer is connected to the unit, the LCD panel
displays
Available.
The LCD panel also allows you to configure network settings for the analyzer.
Use the
Up
and
Down
keypad buttons to cycle through the menu. Press the
Center
button to select.
Setup Static or Dynamic IP Mode
1.
Use the
Up
and
Down
buttons to navigate to the
Set IP Configuration
menu.
2.
Press the
Center
button to start the setup.
3.
Use the
Up
and
Down
buttons to select
Static
or
Dynamic
IP configuration.
4.
If you select the Static IP network configuration, you must specify the
IP address, Subnet mask, and Gateway. Use the
Up
and
Down
buttons
to navigate to the IP address, Subnet mask, or Gateway.
5.
Press the
Center
button to enter edit mode.
6.
In edit mode, use the
Left
and
Right
buttons to move the blinking
cursor to any digit.
7.
Use the
Up
and
Down
buttons to modify the digit.
8.
After finishing modifications to the IP address, Subnet mask, or
Gateway, press the
Center
button to return to the menu.
9.
After you specify the IP address, Subnet mask, and Gateway, use the
Up
and
Down
buttons to navigate to the
Accept and Reboot
menu
item. Press the
Center
button to apply the new settings and restart the
analyzer.
Note:
To cancel your modifications, select the
Cancel Changes
menu
item.
Warning
!
Do not open the enclosure. No operator
serviceable parts are inside.
1
5
4
5
3
2
6
7
12
8
13
9 10 11
7
15
14
4
5
Sync Out Sync In
AC Connector
Unpacking the Analyzer
Inspect the received shipping container for any damage. Unpack the container and account for each of the system components listed on
the accompanying packing list. Visually inspect each component for absence of damage.
In the event of damage, notify the shipper and Teledyne LeCroy. Retain all shipping materials for shipper’s inspection.