PP022 Passive Probe 

EC Declaration of Conformity 

The probe is marked with this symbol to show compliance was 

demonstrated to the specifications listed in the Official Journal of 

the European Communities: Low Voltage Directive 2006/95/EC: 

EN 61010-031/A1:2008 Safety requirements for electrical equipment for 

measurement, control and laboratory use – Part 031: Safety requirements 

for handheld probe assemblies for electrical measurement and test. 

EU RoHS Compliance 

The probe and its accessories conform to the 2011/65/EU RoHS2 Directive, 

as they have been classified as Industrial Monitoring and Control 

Equipment (per Article 3, Paragraph 24) and are exempt from RoHS 

compliance until 22 July 2017 (per Article 4, Paragraph 3). 

General Safety Information 

Observe generally accepted safety procedures in addition to those 

listed here to avoid personal injury or damage to equipment. The 

overall safety of any system incorporating this accessory is the 

responsibility of the assembler of the system. 
Connect only to grounded instruments. Use only with compatible Teledyne 

LeCroy oscilloscopes that have their BNC input connected to an earth 

ground. Do not connect the probe reference lead to any point which is at a 

potential other than earth ground. 
Connect and disconnect properly. Connect probe to the oscilloscope before 

connecting it to the test circuit. Disconnect the probe input and reference 

lead from the test circuit before disconnecting from the oscilloscope. Do 

not connect or disconnect probes while they are connected to a voltage 

source. 

Содержание PP020-1

Страница 1: ...Operator s Manual PP022 Passive Probe...

Страница 2: ...educational purposes Teledyne LeCroy is a registered trademark of Teledyne LeCroy Inc Other product or brand names are trademarks or requested trademarks of their respective holders Information in th...

Страница 3: ...OTECTIVE EARTH TERMINAL Introduction The Teledyne LeCroy PP022 is a passive high impedance voltage oscilloscope probe designed and calibrated for use with general purpose oscilloscopes having an input...

Страница 4: ...30 C 5 to 75 RH 30 C to 40 C 5 to 50 RH above 40 C RH not controlled below 10 C Operating Altitude 3000 meters maximum To reduce risk of fire or electric shock do not exceed the voltage or category r...

Страница 5: ...Operator s Manual 3 PP022 Input Impedance Profile Voltage vs Frequency Derating Curve...

Страница 6: ...iance until 22 July 2017 per Article 4 Paragraph 3 General Safety Information Observe generally accepted safety procedures in addition to those listed here to avoid personal injury or damage to equipm...

Страница 7: ...or cause other bodily injury if not handled properly Keep fingers behind the finger guard of probe body and accessories Do not operate with suspected failures Before each use inspect the probe and acc...

Страница 8: ...n oscilloscopes Low Frequency 1 Apply a 1 kHz square wave to the probe or connect to the oscilloscope s calibrator output 2 Adjust the single LF trimmer located on the PP022 BNC Box until you achieve...

Страница 9: ...the probe at the time of shipping To replace the ground lead with the swivel lead adapter unscrew the short collar from the probe and remove the ground lead Replace the short collar to hold the swivel...

Страница 10: ...105 Long Collar 1 7 PK5 2 5MM 106 IC Tip Insulators Black Brown Blue Green Gray 5 8 PK5 2 5MM 107 Tip Insulator 2 5mm 1 9 PK5 2 5MM 108 Probe Tip Cover 1 10 PK5 2 5MM 109 BNC Adapter 2 5mm 1 11 PK5 2...

Страница 11: ...oy at its option will either repair or replace any assembly returned within the warranty period to the Customer Service Department of an authorized service center However this will be done only if the...

Страница 12: ...925924 00 May 2015...

Отзывы: