This procedure describes the assembly process for the Type 2260 bracket (to install the other types follow the 
same procedure):
1. Place the Extension bracket aligned with the counter sink screw holes. 
2. Make sure the text  "Type 2260" on the bracket is facing the top of the PCB where the cables are attached.
3. Insert the screws and tighten them using a 1.4mm Phillips or flat blade screw driver.

4. The view from the top side of the PCB is shown below. The text "Type 2260" is clearly visible.

Interposer DUT Standoff Installation

A flexible attachment M.2 standoff assembly is provided for the different types of DUTs supported which are 
2240, 2260, 2280, and 22110. Move the M.2 standoff based on the DUT Type. The standoff will be attached to 
2280 location by default. The standoff has a nut on the bottom side which can be removed by hand or with a nut 
driver (see drawings on next page).

4

Warning

!

Attempting to use the board without the extension bracket and properly secured to the host will cause 
damage to the plug-in card of the interposer cable and warranty will be voided.

Содержание PCI Express M.2

Страница 1: ...uite installation DVD 1 Introduction The Teledyne LeCroy PCIe 3 0 M 2 Interposer which is used with Summit Protocol Analyzers enables PCIe bus traffic between a system board or tablet and a M 2 NGFF c...

Страница 2: ...non storage devices Socket 3 keyed as M is strictly for high performance storage offering x4 lanes of bandwidth in this form factor In some cases a B M keyed SSD will also be available and it is both...

Страница 3: ...nnectors in the right orientation following labels and do not force them The Extension brackets are provided to allow the user to attach and secure the Teledyne LeCroy M 2 interposer cable on the host...

Страница 4: ...shown below The text Type 2260 is clearly visible Interposer DUT Standoff Installation A flexible attachment M 2 standoff assembly is provided for the different types of DUTs supported which are 2240...

Страница 5: ...Exploded View Installed Side Profile Installed...

Страница 6: ...rposer Make sure that the AC adapter is powered on 8 Power on the analyzer 9 Power on the host machine 10 Launch the Teledyne LeCroy software application to monitor record and view PCI Express traffic...

Страница 7: ...ck Select CABLE Clock Source 1 2 3 4 Clock Source B HOST_CLK ON ON N A N A Downstream sourced with host clock B DS_CLK ON OFF N A N A Downstream sourced with external input DS_CLK A US_CLK N A N A OFF...

Страница 8: ...are updates are available to users with a current Maintenance Agreement Web teledynelecroy com tm software PCIe E mail psgsupport teledyne com Support teledynelecroy com support contact 2013 Teledyne...

Отзывы: