background image

Trademarks and Servicemarks

Teledyne LeCroy, PCIe Protocol Analysis, and Summit T516 are 

trademarks of Teledyne LeCroy. All other trademarks are property 

of their respective companies.

Changes

Product specifications are subject to change without notice.

Teledyne LeCroy reserves the right to revise the information in this 

document without notice or penalty.

Teledyne LeCroy Customer Support

Online Download
Periodically check the Teledyne LeCroy Protocol Solutions Group 
web site for software updates and other support related to this 
product. Software updates are available to users with a current 
Maintenance Agreement. 

Web: 

teledynelecroy.com/tm/software/PCIe

E-mail:

[email protected]

Support:

teledynelecroy.com/support/contact

© 2020 Teledyne LeCroy, Inc. All rights reserved.

                   Part Number: 932327-00   Rev B

This document may be printed and reproduced without additional permission, but all copies should contain this copyright notice.

     Environmental Conditions

Temperature: Operating 32° F to 122° F (0° C to 50° C) 

Temperature: Non-Operating 14° F to 176° F (-10° C to 80° C)

Humidity: Operating 10% to 90% RH (non-condensing)

8

Содержание PCI Express 5.0 x16 Slot Interposer

Страница 1: ...o a PCIe CEM Connector and allows you to probe PCI Express traffic between a host and a PCIe expansion card The interposer assures reliable data transmission while providing 100 capture of all data tr...

Страница 2: ...e allows recording for up to x8 links at up to 32 0 GT s with single Summit T516 and a Gen5 x16 CEM Interposer See Summit T516 Analyzer documentation for connectivity and configuration details Gen5 to...

Страница 3: ...ond Gen5 to Gen5 x8 Y cable PE028UCA X to the US 0 15 connector on the interposer a Connect the cable connector labeled B to the connector A on the Summit T516 b Connect the cable connector labeled A...

Страница 4: ...A C B D A B A B Clock source configuration switch SW2 see table below Summit T516 Analyzer Host Power LEDs 12V 3 3V and 3 3V Aux Y cable Downstream PE028UCA X Y cable Upstream PE028UCA X External ups...

Страница 5: ...ER REFCLK SEL Port B 1 2 Port A 3 4 REFCLK ON ON REFCLK ON ON US_CLK_IN OFF ON US_CLK_IN OFF ON DS_CLK_IN ON OFF DS_CLK_IN ON OFF N A OFF OFF N A OFF OFF Pushbutton SW3 is used to turn off the termina...

Страница 6: ...of the DUT s metal flange Fully insert the DUT in the top connector of the interposer Then use the thumbscrew in the DUT retention clamp to secure the DUT See the drawings below DUT Retention Clamp F...

Страница 7: ...racket Save the screws for installation of the half height bracket Gen5 x16 Interposer with Full Height Bracket Attached and Removed Locate the Half height bracket and the two screws from the disassem...