Teledyne Lecroy frontline SODERA Скачать руководство пользователя страница 2

Frontline Technical Support:email [email protected] or [email protected]

Sodera Front Panel Controls and Indicators

Power On/Off Button

: Press and hold the button for at least 1/2 second, and then release the button to power on or power off the

system.

Pressing and holding the button for at least five seconds will initiate an

emergency shut down

sequence.

Status Indicators

: Colored LEDs show the status of power and capture.

Indicator

Color

State

Status Indicated

Power

None

Off

Unit is powered off

Green Constant

Unit is switched on

Red

Blinking

Unit is approaching its maximum thermal load and should be shut
down.

Constant

Unit has been automatically disabled due to thermal overload.

Amber Constant

Unit is powering down.

Battery State

None

Off

No battery present

Green Constant

Battery present and is at normal operating voltage

Slow Flash

Battery charging

Amber Fast Flash

Battery fault

Host Interface

None

Off

No host interface is connected.

Green Constant

Host interface is connected.

Amber Constant

Internal error

Capture

None

Off

Unit is not actively capturing data

Green Constant

Unit is capturing data

Red

Constant

Unit has engaged RF overload protection; the RF signal is too strong.

Table 1 - Sodera Front Panel Status Indicators

Antenna SMA Connector

: Antenna attaching point.

Battery Charge

: The following table shows the charge state of the installed battery. When the battery is not installed, all LEDs are off

except when the unit is in the process of powering up. In that case they repeatedly light up in sequence.

Indicator LEDs

Charge Status

Greater than 80%

Between 60 and 80%

Between 40 and 60%

Between 20 and 40%

Table 2 - Sodera Battery Charge State

LED Indicators

Содержание frontline SODERA

Страница 1: ...drive 20 GB Install Software l From Download Download the latest Frontline installer from FTE http fte com sodera soft Once downloaded double click the installer and follow the directions When the in...

Страница 2: ...attery State None Off No battery present Green Constant Battery present and is at normal operating voltage Slow Flash Battery charging Amber Fast Flash Battery fault Host Interface None Off No host in...

Страница 3: ...g multiple capture devices Sodera can act as a clock source master device providing the clock to synchronize timestamping with connected target slave devices When operating as a master device the OUT...

Страница 4: ...WiFi technologies One device will act as the master device by providing the clock to the slave device receiving the clock The devices are connected in a daisy chain configuration The Sodera unit must...

Страница 5: ...rear panel 3 Install the battery To start the Sodera Analyzer depress the Power button on the front panel for at least 1 2 second and then release This action will provide a clean start for Sodera har...

Страница 6: ...psgsupport teledyne com Wireless Protocol Suite Start Page Select Sodera to bring up the Wireless Protocol Suite window The Wireless Protocol Suite Application Eicon icon will be placed in your taskba...

Страница 7: ...channels storing data for both live and post capture analysis Sodera uses a two stage capture analysis process First Record will activate the Sodera datasource to begin capturing data from all Bluetoo...

Страница 8: ...The user can configure the datasource from the Options menu The default settings are sufficient for capturing most Bluetooth connections Details of the configuration settings are in the Wireless Prot...

Страница 9: ...View will begin to populate with information warnings and error messages The Status Bar will show a running total of captured packets Note Starting a new capture session will clear all unsaved data fr...

Страница 10: ...alyzer will begin sending captured packets involving the selected device s to the Wireless Protocol Suite software Once analysis has begun you cannot change the device selection All device rows in the...

Страница 11: ...rce l or the Start Recording under the Capture option in the Main window The Sodera analyzer will begin capturing data from all wireless devices within range and from all connected wired devices 2 In...

Страница 12: ...F l Power Input 12 VDC tip positive l Max Power 25 W l Battery NB2037FQ31 Caution There is a risk of explosion if the battery is replaced by an incorrect type Dispose of old batteries according to yo...

Страница 13: ...Frontline Technical Support email frontline techsupport teledyne com or psgsupport teledyne com Publish date 8 20 2020...

Отзывы: