Frontline Technical Support: [email protected]

On the

Wireless Protocol Suite

Toolbar, clicking on the

Stop Record

button, or selecting

Stop Recording

from the

Capture

menu options will halt live capture. From the Main window you can click the

Stop Record

button or

select

Stop Recording

from the

Captur

e menu list to stop recording as well.

The

Device Database

View populates with any newly discovered devices. Selecting devices for analysis can be done while recording.

The

Security

View will show all encrypted

Bluetooth

links.

The

Event Log

View will begin to populate with information, warnings, and error messages.

The

Status Bar

will show a running total of captured packets.

Note:

Starting a new capture session will clear all unsaved data from both the Sodera hardware and the

Wireless Protocol Suite

. If it has not been saved, then a pop-up warning message will appear.

8. Selecting Devices for Analysis

Once a capture session starts by clicking on

Start Record

on the Main Window Toolbar, data from all active devices within range or

data from wireless or wired connections is being captured. To analyze the data using the

Wireless Protocol Suite

, select specific

devices of interest to include in the analysis.

In the

Device Database

view, place a check in the row of each active device

to be analyzed. Active devices can also be selected

while the recording is in process.

Note:

Data filtered by the device selection is an “OR” function, not an “AND” function. When selecting device1,

device2, device3,... the recorded data filtered into the analyzer is data involving device1 OR device2 OR device3
OR .... However, if in the Options menu, analysis of LE Empty packets is selected, an AND function is included.
For example: (device2 AND LE Empty packets) OR (device3 AND LE Empty packets).

The following table lists some common data capture and device selection scenarios.

Once Devices are selected, analysis of the capture can begin.

9. Starting Analysis

The analysis begins by clicking on the

Start Analyze

button in the

Wireless Protocol Suite

Main window. The

Sodera LE analyzer will begin sending captured packets involving the selected device to the

Wireless Protocol

Suite

.

Once analysis has begun, you cannot change the device selection. All device rows in the

Device Database

View are

grayed-out. To stop the analysis, click on the

Stop Analyze

button. You can then change your device selection and

restart analysis by clicking on the

Start Analyze

button.

To stop the analysis, click on the

button in the Sodera datasource or click the

button on

the

Wireless Protocol Suite

Main window You can also select the

Stop Analyze

option in the

Capture

menu in the Sodera datasource

or

Stop Analyzing

option in the

Capture

menu in the Main window as well.

Conducting analysis from a capture file is identical to the live capture method.

Wireless Protocol Suite

: Main Window

Wireless Protocol Suite

: Main Window

Содержание Frontline Sodera LE

Страница 1: ...nce downloaded double click the installer and follow the directions When the installation is complete pin the Wireless Protocol Suite icon to your taskbar 1 Sodera LE Front Panel Frontline Sodera LE f...

Страница 2: ...powered up using the power button See Table 2 Sodera LE Front Panel Power and Overload Indicators on page 2 for more information EXT CLOCK Not used Power Button Press and then release the button to po...

Страница 3: ...sides This connector provides host computer command control and data transfer Note All other connectors are not used 3 Attach Antenna Antenna Attachment Point Remove the Frontline Sodera LE hardware f...

Страница 4: ...This action will provide a clean start for the Sodera LE hardware The front panel Power LED indicator will be green Should the Sodera LE hardware reach thermal overload temperature between 50 C and 6...

Страница 5: ...LE option Wireless Protocol Suite Start Page Select Sodera LE to bring up the Wireless Protocol Suite window When the Main Application Window is Displayed you will see toolbars with the following fun...

Страница 6: ...vices is cleared in the Device Database pane and the Wired Devices pane l The Security pane is emptied l The Event Log pane retains all prior logged events On the Wireless Protocol Suite Toolbar click...

Страница 7: ...selected while the recording is in process Note Data filtered by the device selection is an OR function not an AND function When selecting device1 device2 device3 the recorded data filtered into the a...

Страница 8: ...e Start Record under Capture in the datasource l or the Start Recording under the Capture option in the Main window The Sodera LE analyzer will begin capturing data from all wireless devices within ra...

Страница 9: ...p mode the user should close and then restart the Frontline software 11 Sodera LE Technical Specifications Service Information l Dimensions 160 mm wide X 56 mm tall X 167 mm deep 6 3 X 2 2 X 6 6 l Wei...

Отзывы: