Output ring terminals

single-hole

Telect 104987

ETSI Mounting bracket

black

Telect 090-0041-0230

ETSI Mounting bracket

white

Telect 090-0041-0231

Phoney fuses - KLM

Non-functional fuses

Telect 110852

Phoney fuses - GMT

Non-functional fuses

Telect 132748

KLM/GMT Designation Label

Removable

Telect 117750-1

GMT Fuses

Color

Telect 
Part 
Number

Colored 
Designation 
Rivet

KLM 
FUSE 
AMPERA

Telect 
Part 
Number

Dummy fuse 
(GMT)

N/A

132748

N/A

Dummy Fuse

110852

1/4A

Violet

100151

102435-2

1 A

118675

1/2A

Red

004001

102435-5

2 A

118676

3/4A

Brown

004008

102435-7

5 A

118673

1A

Gray

100991

102435-8

10A

118438

1 1/3A

White

004006

102435-9

15 A

118439

1 1/2A

White/yellow

004011

102435-10

20A

118440

2A

Orange

004002

102435-11

25A

118441

3A

Blue

004012

102435-13

30A

118442

4A

White/brown

004013

102435-15

5A

Green

004014

102435-16

7 1/2A

Black/white

004010

102435-17

10A

Red/white

004015

102435-18

12A

Yellow/green

102287

102435-19

15A

Red/blue

102288

102435-20 

Item

Description

Part Number

Содержание 009-8004-0208

Страница 1: ...8x8 KLM GMT Power Distribution Panel Model 009 8004 0208 Installation Guide ...

Страница 2: ... and the products described herein are subject to change without notice About Telect Telect offers complete solutions for physical layer connectivity power equipment housing and other network infrastructure equipment From outside plant and central office to inside the home Telect draws on more than 25 years of experience to deliver leading edge product and service solutions Telect is committed to ...

Страница 3: ...nnecting to the Power Bays 6 1 4 4 Supplying Testing Input Power 6 1 4 5 Testing the Input Power Alarm Relays 6 1 4 6 Connecting Output Cables 7 1 5 General Guidelines for Installing Fuses 8 1 5 1 Installing KLM Fuses 8 1 5 2 Installing GMT Fuses 9 1 5 3 Testing the Fuse Alarm Relays 9 1 5 4 Fuse Alarm Visual Indicator Test 9 1 6 Powering the Load Equipment 10 1 7 Replacing the Alarm Card 11 1 8 R...

Страница 4: ...836 37 52 www telect com 2010 Telect Inc All Rights Reserved 117200 4 A0 List of Figures Figure 1 Model 009 8004 0208 1 Figure 2 Grounding 4 Figure 3 Power connection 5 Figure 4 Test Guide 6 Figure 5 Connecting Output Cables 7 Figure 6 Fuse Alarm Card 9 ...

Страница 5: ...ting in an EIA or WECO rack The panel is configured at the factory for extended mounting in a 19 rack ETSI mounting kits are also available contact Telect or your distributor Model 009 8004 0208 is UL Listed File E139903 and NEBS Certified 1 2 Specifications Physical Dimensions with brackets Width 17 50 in 44 45 cm Height 3 47 in 8 81 cm Depth 9 00 in 22 86 cm Weight without fuses 13 5 lbs 6 12 kg...

Страница 6: ... Quantity 24 Cable 22 26 AWG Output terminals Quantity 32 16 BATT 16 RTN Screw size 8 32 wire clamping Cable 22 to 10 AWG rated to output fuse size Maximum torque 9 in lb 1 01 N m Output Terminal maximum lug width 5 16 in 0 79 cm GMT fuse Insertion Withdrawal force Insertion 7lbs 3 1lbs 3 18 kg 1 41 kg Withdrawal 5 5 lbs 2 5 lbs 2 49 kg 1 13 kg KLM fuse Insertion Withdrawal force Maximum Average f...

Страница 7: ...com website or email inquiries to getinfo Telect com and click on the Support tab or phone us at 800 551 4567 domestic only or 509 926 6000 Alarm contact ratings continuous 2A at 30 VDC 0 6A at 60 VDC 1A at 120 VAC Alarm board power ratings 20V 100 mA 2 W 24V 153 mA 3 672 W 27V 166 mA 4 48 W 30V 167 mA 5 01 W 42V 173 mA 7 27 W 48V 175 mA 8 4 W 56V 179 mA 10 02W 60V 181 mA 10 86 W Max operating tem...

Страница 8: ...e equipment 1 4 1 Installing and grounding the panel 1 Clean all contact surfaces 2 Mount the panel using the four screws and star wash ers provided 3 Tighten the screws to 35 in lb 4 29 N m 4 Secure the compression lug to the grounding studs with the 10 24 hex nuts provided 5 Torque the nuts to 20 in lb 2 26 N m with a 3 8 inch 10 mm socket 6 Attach the ground cable s to the ground relay rack or ...

Страница 9: ...for both A and B input power circuits Use properly rated ca bles and two hole compression lugs The cables may require 45 or 90 lugs 3 Insulate the lug barrels with UL94V0 rated heat shrink tubing as shown It may be necessary to cover the lug inspection hole with the tubing 4 For assistance refer to the operating com pany s installation procedures 5 Locate the two input power terminals Input A and ...

Страница 10: ...nded Before supplying input power verify that the KLM PDP has no fuses installed This measure prevents power from reaching any output path Failure to do so could result in hazardous conditions Terminate power cables from the PDF at the correct BATT and RTN input lugs on the KLM PDP Test polarity at these input lugs using standard procedures 1 4 5 Testing the Input Power Alarm Relays Test the Power...

Страница 11: ...ith UL94V0 rated heat shrink tubing For assistance refer to the operating company s installation procedures 2 Locate Side A output power terminals on the KLM PDP back plane Loosen and remove the plastic terminal covers 3 Clean the contact areas of the compression lugs and the BATT and RTN output terminals Use a coarse non metallic cleaning pad 4 Remove all power cards and or equipment fuses from e...

Страница 12: ...for Side B 13 Re install the plastic terminal block covers 14 Use designation labels to record output equipment KLM connections A 1 through A 8 and B 1 through B 8 and GMT connections according to the operating company s standard installa tion procedures 1 5 General Guidelines for Installing Fuses DANGER DANGER The maximum rated load current for each fuse position must not exceed 25 amps for KLM f...

Страница 13: ...uipment damage or equipment service interruptions Test fuse alarm relays using standard operating company procedures 1 5 4 Fuse Alarm Visual Indicator Test Observe the KLM PDP s alarm card while performing the following test for fuse alarm visual indicators Figure 6 Fuse Alarm Card 1 Install a known good correctly rated fuse in any KLM position The alarm card s Alarm LED for that position is off u...

Страница 14: ...lacing fuse will turn LED to GREEN Power A or Power B LED is OFF No change Power alarm relay is still on Power A and Power B LEDs are turned green normal only by restoring power Power alarm relays are only cleared by restoring power Any condition All LEDs turn AMBER All remote alarm relays switch to alarm condition Notify alarm center before test This test condition clears whe button is released p...

Страница 15: ... Phillips screwdriver to secure the card s captive screws just beyond finger tightness 7 If desired test the alarm card according to the alarm testing procedures above Telect alarm cards are factory tested Replacement testing may not be advisable if it affects office system service 1 8 Replacing Fuses WARNING WARNING Only install UL listed or R C Supplementary Protectors in the output fuse holder ...

Страница 16: ... NOTE Call a Customer Service Representative for a Return Material Authorization RMA before returning any equipment 1 9 2 Out Of Warranty Service The procedure for out of warranty service is the same as for in warranty service except that Telect charges a processing fee and you must submit a purchase order along with a Return Material Authorization RMA before returning equipment Call a Telect cust...

Страница 17: ... Part Number Colored Designation Rivet KLM FUSE AMPERA Telect Part Number Dummy fuse GMT N A 132748 N A Dummy Fuse 110852 1 4A Violet 100151 102435 2 1 A 118675 1 2A Red 004001 102435 5 2 A 118676 3 4A Brown 004008 102435 7 5 A 118673 1A Gray 100991 102435 8 10A 118438 1 1 3A White 004006 102435 9 15 A 118439 1 1 2A White yellow 004011 102435 10 20A 118440 2A Orange 004002 102435 11 25A 118441 3A ...

Страница 18: ...KLM 1 KLM 1 KLM 6 KLM 6 KLM 2 KLM 2 KLM 7 KLM 7 KLM 3 KLM 3 KLM 8 KLM 8 KLM 4 KLM 4 GMT GMT KLM ALARM 4 KLM ALARM 8 KLM ALARM 1 KLM ALARM 5 KLM ALARM 3 KLM ALARM 7 KLM ALARM 2 KLM ALARM 6 KLM ALARM 2 KLM ALARM 6 KLM ALARM 3 KLM ALARM 7 KLM ALARM 1 KLM ALARM 5 KLM ALARM 4 KLM ALARM 8 NO NO NC NC C C Note Relays shown in alarm state 48V 48V 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 ...

Страница 19: ...butes Telect assumes no liability from the application or use of these products Neither does Telect convey any license under its patent rights or the patent rights of others This document and the products described herein are subject to change without notice Rear View Front View 8x8 KLM Power Distribution Panel PN 009 8004 0208 3 47 in 8 81 cm ...

Страница 20: ...Page 16 Telect Inc USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 117200 4 A0 This page intentionally left blank ...

Отзывы: