THOR-E Extender
08-23-2011
7.1.9
Digital Audio Interface
The digital audio option supports the unidirectional transmission of digital
audio data.
Up to three sources can be connected to the CPU Unit. The active source
is transmitted. If several sources are active, the XLR signal takes priority,
otherwise the first active signal.
Up to three sinks can be connected to the CON Unit. The signal is
available at all outputs concurrently.
THOR-E Extender with digital audio option include an inbuilt sample rate
converter that allows to provide predefined sample frequencies at the
output of the CON unit.
The User can set directly the following parameters by using a
configuration file:
Activate oder deactivate sample rate converter
Set sample frequency of the sample rate converter. The following
sample frequencies are available:
–
32.0 kHz
–
44.1 kHz
–
48.0 kHz
–
96.0 kHz
Compatibility
AES/EBU, S/PDIF, EIAJ CP1201,
IEC 60958
Standards
Dolby Digital, DTS, PCM
Scanning Frequency
32 to 96 kHz
CPU Unit (Inputs)
Mini-XLR (AES/EBU; symmetrical,
lockable)
Coaxial (S/PDIF; RCA, Cinch)
Optical (S/PDIF; TOSLINK)
CON Unit (Outputs)
Mini-XLR (AES/EBU; symmetrical,
lockable)
Coaxial (S/PDIF; RCA, Cinch)
Optical (S/PDIF; TOSLINK)