28
Table 7: 4-Wire Intercom Connections
PIN
FUNCTION
IMPEDENCE
SIGNALS
1
Ground
2
Input (+)
Line: +8 dBm
3
Input (-)
600 Ohm input
Mic: -32 dBm
4
Out (+)
5
Out (-)
>=600 Ohm
load
+8 dBm
Figure 27: Intercom Module: 4-Wire Auxiliary (balanced)
Clear-Com
Clear-Com intercom modules have a 3-pin XLR connector for each of the A and B channels.
This Telecast module fully supports the Clear-Com signaling protocol and signal levels.
The Clear-Com Intercom Connections are listed in Table 8.
Table 8: Clear-Com Intercom Connections
PIN
FUNCTION
1
Ground
2
+VDC Power
3
Power
Note:
When using the Clear-Com external power supply, pin 3 termination must be lifted on the
power supply to prevent motor-boating.
Clear-Com channel operation is optimized by the use of the front panel adjustments shown in
Figure 28 and listed below:
• Input Gain, ±10 dB
• Output Gain, ±10 dB
• Null
Switches are also provided for the channel pair for:
• Dry unpowered (d), or Wet powered (w) PORTS
• 200 Ohm on or off terminations TERM