System Overview 

1 - 3 

Doc.

DM375-I

 

Ver. 

1.0

 

 

2.

 

The IP modules (mIP/IPDACTs) 

The IP Modules (mIP/IPDACTs) connected to the client control panel carry out two tasks: 

1.

 

Capture the alarms sent by the control panel and send them over the IP network to which they 
are connected.  These alarms are then received by the Teldat VisorALARM PLUS 2U in order 
to be sent to the corresponding automation software (SwAut). 

2.

 

Generate  monitoring  traffic  so  that  both  ends  of  the  security  environment  check  the  IP 
connectivity, permitting the above task to be accomplished. 

The  mIP/IPDACT  is  a  device  that  intercepts  the  control  panel  telephone  connection  with  two  aims: 
firstly to detect when the panel sends an alarm in order to capture and retransmit it over the connected 
IP network and secondly to allow the telephone line to be used at the same time as sending alarms. 

The interception of the telephone line takes place ONLY in cases where connectivity with the Teldat 
VisorALARM PLUS 2U has been verified.  The mIP/IPDACT - VisorALARM PLUS 2U connectivity 
is  checked  through  a  traffic  monitor  which  the  mIP/IPDACT  periodically  sends  and  to  which  the 
Teldat  VisorALARM  PLUS  2U  responds.    If  this  exchange  of  messages  does  not  occur  during  the 
configured time, the mIP/IPDACT tries to resend.  If after a configurable number of attempts (between 
1 and 9), a satisfactory response is not received, the connectivity is presumed lost.  The time between 
polling messages is programmable between 0 and 90 seconds, a typical value being 15 seconds.  The 
time between retries is also configurable, between 3 and 9 seconds. 

If  a  network  backup  scheme  is  running,  the  mIP/IPDACT  has  a  second  IP  receiver  to  establish 
communications  and  send  alarms.    If  this  second  receiver  does  not  respond  to  the  communication 
established with it by the mIP/IPDACT (again after a configurable number of attempts), the telephone 
line access is returned to the control panel as if the mIP/IPDACT was no longer operative at the alarm 
level.    From  this  point  on,  the  mIP/IPDACT  will  try  to  re-establish  communications  with  both  the 
main  Teldat  VisorALARM  PLUS  2U  as  well  as  the  backup,  if  there  is  one.    As  soon  as  this  is  re-
established with either of the VisorALARM PLUS 2U, the mIP/IPDACT will intercept the telephone 
line once more. 

The monitoring traffic is encrypted UDP traffic.  The Ethernet frame size does not exceed 70 bytes.  
The monitoring interval, the number of retries and time between retries are all configurable, both for 
the main VisorALARM PLUS 2U as well as for the backup.  The time between retries is an important 
parameter as it influences the global traffic supported by the VisorALARM PLUS 2U (polling over all 
the devices).  You also need to bear in mind that polling is a tool to control the state of both the alarm 
reception center and the mIP/IPDACT.  A long interval between polls can lead to situations where the 
VisorALARM  PLUS  2U  delays  detecting  a  problem  with  the  mIP/IPDACT  and  consequently  a 
problem  with  a  customer.    Finally,  if  the  mIP/IPDACT  accesses  the  Internet  via  a  device  which 
executes NAT, traffic coming from the VisorALARM PLUS 2U (configuration for example) will not 
reach  the  mIP/IPDACT  if  the  period  between  polls  is  inferior  to  the  outgoing  router  NAT  tables 
refresh time (a typical refresh value is 5 minutes). 

The Teldat VisorALARM PLUS 2U receives monitoring messages from the mIP/IPDACTs.  If these 
are  registered,  they  are  assumed  alive  and  an  acknowledgement  response  is  sent  to  them;  if  the 
mIP/IPDACTs  are  not  registered,  they  are  ignored.    Periodically  the  status  of  all  the  registered 
mIP/IPDACTs  is  checked  and  an  alarm  is  generated  for  all  those  which  have  not  notified  their 
availability (i.e. those which have not responded since the last check).  This is a 350 code alarm from 
the Contact-ID protocol (

Communication trouble

) which is received in the SwAut.  Default is 350.  As 

each  mIP/IPDACT  can  have  a  different  polling  time  with  the  center,  the  VisorALARM  PLUS  2U 
checks the status of each mIP/IPDACT according to the polling time value for each of them. 

In  order  to  prevent  the  Teldat  VisorALARM  PLUS  2U  from  sending  hundreds  or  thousands  of 
communication failure alarms when faced with a situation of general failure of IP traffic reception, the 
device itself monitors the network access through ICMP echo packets (ping) to a known address: if the 

Содержание VisorALARM PLUS 2U

Страница 1: ...VisorALARM PLUS 2U Operating Instructions Doc DM375 I Rev 1 0 May 2007...

Страница 2: ...ATORS 1 1 UNIT CONTROLS AND INDICATORS 2 1 1 LCD Display 2 1 2 LED Indicators 2 1 3 Keypad 3 1 4 Local Piezo Sounder 4 CHAPTER 3 OPERATING VISORALARM PLUS 2U 5 1 ACCESSING THE RECEIVER 6 2 OPERATING I...

Страница 3: ...Chapter 1 System Overview...

Страница 4: ...ally signal the reception of new signals It also provides specific function keys to manually acknowledge every received signal The IP VisorALARM PLUS 2U receiver operates together with the IP Module m...

Страница 5: ...th both the main Teldat VisorALARM PLUS 2U as well as the backup if there is one As soon as this is re established with either of the VisorALARM PLUS 2U the mIP IPDACT will intercept the telephone lin...

Страница 6: ...onfiguration patterns associated to installer passwords These permit you to automatically register new mIP IPDACTs in the supported mIP IPDACT list and at the same time enable the mIP IPDACT to reques...

Страница 7: ...d also remotely telnet In both cases the access is restricted to users who are identified by a user name and a password Also the receiver can be monitored through a local console remotely through teln...

Страница 8: ...Chapter 2 Controls and Indicators...

Страница 9: ...line of the display shows the type of the receiver this can be PRIMARY BACKUP or Maintenance Receiver Second line shows the status of the receiver 1 2 LED Indicators LED Indicators are provided to ann...

Страница 10: ...icator com2 not active Upload download communication in progress through com2 Upload download communication established through com2 1 3 Keypad The unit keypad includes 5 function keys and 12 addition...

Страница 11: ...1 0 1 4 Local Piezo Sounder A piezo sounder provides distinct audible indications for alarm trouble and supervisory signals Signal Sound Alarm Sounds continuously Supervisory Sounds on and off at a h...

Страница 12: ...Chapter 3 Operating VisorALARM PLUS 2U...

Страница 13: ...n the figure The numeric keys must be used to introduce a valid numeric password for the system There are three privilege levels with different passwords to access the receiver The default receiver pa...

Страница 14: ...be prompted for a password Upon entering the password the event with the highest priority is resounded Repeatedly pressing the ACK key will now display and acknowledge subsequent events Subsequently...

Страница 15: ...e a signal the user must press the ACK key again If there are more pending signals the receiver shows the following And the user must press the ACK again in order to visualize the highest priority sig...

Страница 16: ...signals are automatically sent to the Automation Software for acknowledgement Signals are also stored in the signal database for further review and the ACK and TRB LEDs still indicate alarm signals an...

Страница 17: ...e User Mode root menu options When navigating by menus the key goes back to the previous menu If the menu is the USER MODE root menu the receiver exits the root menu and resumes normal or automatic op...

Страница 18: ...ignal history log can be reviewed using different search criteria This option is described in depth in next paragraphs The Account Status option enters the ACCOUNT STATUS menu where the status and com...

Страница 19: ...e The first four options represent different search criteria over the signal history database the option Info will display the total number of stored signals and the percentage of occupation The Clear...

Страница 20: ...he Local Piezo Sounder Hdw failure Printer Printer not detected Network failure The device specified in the monitor_ip_address configuration parameter does not answer Probably the internet link is dow...

Страница 21: ...3 E 4 F 5 The left key has the Clear function to delete previous digits and the ACK key clears all the digits When the account code is completed the user must press the OK key to validate the code As...

Страница 22: ...tes are State Description Alive Device is all normal Supervision messages for the device are received as expected Registered Device is not connected Device is present in the Account Database but no me...

Страница 23: ...rial Number 3 The Sw Rls option displays the mIP IPDACT device software release 4 The IP option displays the mIP IPDACT device IP address 5 The Port option displays the mIP IPDACT device UDP port Remo...

Страница 24: ...VisorALARM PLUS 2U Operating III 17 Doc DM375 I Ver 1 0 NOTES...

Отзывы: