![Teldat 4Ge Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/teldat/4ge/4ge_user-manual_1079512012.webp)
hexadecimal digits. For example, the ampersand ( &) would be %26. Thus, to enter an apn equal to ac-
cess&network.es, you can enter apn=access%26network.es.
• Some parameters have a shortened version. For instance, the short version for password is pwd.
The first word in option 43 should be “antenna”. This allows the Teldat 4Ge to accept the address offered by the
router. If you don't use this word, the Teldat 4Ge won't accept the address.
The configuration parameters available for the Teldat 4Ge include:
•
“
pin=NNNN
”
, allows you to configure the PIN number for the SIM card used in the Teldat 4Ge.
•
“
apn=
”
, configures the 4G network APN to which the Teldat 4Ge will be connected.
•
“
apntype=
”
, or
“
type=
”
configures the type of 4G network APN to which the Teldat 4Ge will be connected. This
can be
ipv4v6
or
ipv6
. If this parameter is not configured, it will be
ip
(for IPV4 APNs).
•
“
user=
”
, or
“
usr=
”
, allows you to configure a user for authentication in the cellular operator's APN.
•
“
password=
”
, or
“
pwd=
”
allows you to configure a password for authentication in the cellular operator's APN.
•
“
rxtimeout=T
”
, or
“
rxto=T
”
, indicates that the transmission and reception packets are monitored. If, after T
seconds, no response to a transmitted packet is received, the connection with the router and the WWAN access
module is restarted. You can set a value between 10 and 86399 seconds. By default, this parameter is disabled.
•
“
flowcontrol=N
”
, or
“
flow=N
”
, indicates that the transmission and reception packets are monitored. If nothing is
received after N transmitted packets, the connection with the router and the WWAN access module is restarted.
You can set a value between 1 and 65535 packets. By default, this parameter is disabled.
•
“
ntpserver=AAA.BBB.CCC.DDD
”
, or
“
ntps=AAA.BBB.CCC.DDD
”
, IP address of the NTP server used to syn-
chronize the device time.
•
“
ntpoffset=N
”
, or
“
ntpo=N
”
, the time is expressed in GMT + ntpoffset. The default value is 2 (i.e. GMT + 2). Ac-
ceptable values range from -12 to +12, in 1-hour intervals.
•
“
mode=
”
, allows you to select the technology used to connect to the cellular network. The options are
auto
,
gprs
,
wcdma
,
gprsp
,
wcdmap
,
lte
,
cdma
,
hrpd
and
hybrid
. The
gprsp
and
wcdmap
modes indicate that GPRS and
WCDMA technology, respectively, are preferable. Default is
auto
.
•
“
domain=
”
, or
“
dmn=
”
, allows you to select the domain the device connects to. The options are
cs
,
ps
and
cs+ps
.
As backup support for voice calls hasn't been implemented yet, we recommend using
ps
. Default is
ps
.
•
“
idletime=T
”
, or
“
idle=T
”
, configures the idle time, in seconds, for the 4G network session. After a session has
been established, if the idle time expires without a new packet being received from the router, the Teldat 4Ge con-
siders the session to be down and drops it. Acceptable values range from 0 to 65535 seconds. By default, this
parameter is not configured (which is the same as setting it to 0).
•
“
atafterpin=
”
, or
“
aft=
”
, or
“
beforepin=
”
, or
“
bef=
”
, allows you to configure an additional AT command that is
sent during the 4G module's startup. It is generally used to send a certain network or modem parameter.
•
“
coveragetimer=N
”
, or
“
ct=N
”
, configures the sample period for the 4G network coverage values (Rx_level,
RSCP and EcIo). The N value must be between 10 and 255 seconds. Default is 60 seconds.
•
“
clientid=no
”
, or
“
cid=no
”
, disables sending the
client identifier
in DHCP requests. This is designed for configura-
tions with several Teldat 4Ge devices and Cisco routers.
•
“
regdenied=1
”
, or
“
regd=1
”
, enables a feature that switches off the 4G module radio interface for 5 seconds if the
network initially denies registration (
registration DENIED
). Thus, you have a way to get out of such a situation and
the module can re-register in the 4G network.
•
“
pnum=N
”
, or
“
profilenum=N
”
, selects the call profile that 4Ge uses to make the data call. It allows you to specify
the call profile for modules that provision the APN using
Over The Air
(OTA), without having to specify an APN in
the configuration. It admits values ranging from 1 to 12.
•
“
auth=
”
, if the data APN requires authentication, this parameter allows you to select the type of authentication. The
options are
chap
,
pap
and
none
if no authentication is required. If you don't include this parameter, the default au-
thentication method (
pap
) is used.
•
“
regapn=
”
, or
“
rapn=
”
configures the 4G network registration APN used for the Teldat 4Ge router. If the registra-
tion APN and the data APN are the same, we recommend using
"reagapn="
and
"pnum=1"
.
•
“
regapntype=
”
, or
“
rtype=
”
configures the type of 4G network registration APN used for the Teldat 4Ge router.
The options are
ipv4v6
and
ipv6
. If this parameter is not configured, it will be
ip
.
•
“
regauth=
”
, or
“
rauth=
”
, this parameter allows you to select the type of authentication if the registration APN re-
quires authentication. The options are
chap
and
pap
.
Teldat S.A.
3 Configuration
Teldat 4Ge
9