GB
Function
n. Off On Descrption
Notes
During opening, upon pressing the P/P button the gate stops, pressing it again the gate closes.
During closing, upon pressing the P/P button the gate stops, pressing it again the gate opens.
During opening, upon pressing the P/P button the gate stops for a few seconds and then closes.
During closing, upon pressing the P/P button the gate stops for a few seconds and then opens.
During opening, pressing the P/Pbutton has no effect. During the pause, pressing the P/Pbutton has no
effect.
During closing, upon pressing the P/P button the gate stops for a few seconds and then opens.
During opening, pressing the P/Pbutton has no effect. During the pause, upon pressing the P/Pbutton the
gate closes.
During closing, upon pressing the P/P button the gate stops for a few seconds and then opens.
“Hold-to-Run”
Close button
medium-low
Always opens
“Condominium”
Close button
low
OFF
OFF
OFF
ON
ON
ON
Opens-Closes
with no reversal
during opening
SLAVE-INPUT
medium-high
Open - Close
Clock
high
Open - Stop -
Close
The flashing light operates together with the motor.
After one complete opening, the control unit only closes again with a manual control.
Function bypassed
The flashing light operates 5 seconds before any operation.
After one complete opening, the control unit closes automatically after the programmed pause time.
The activation of photoelectric cell reduces the pause time for whatever is value previously was to 2
seconds.
Preflash
Motor speed
Jolly
input mode
Step-by-step
input
and
radio channel
mode (CH1)
Re-closure
Timer
Reclosing after
the photoelectric
cells
CONFIGURATION DIP-SWITCHES
Closes the gate when the contact is opened and opens when the contact is closed.
The control unit performs the commands received from a MASTER control unit
The automation closes when the button is held down. It stops when the button is released.
The P/P button becomes a Hold-to-Run button.
Close start button. The P/P button becomes an Open Command.
This mode enables control of a courtesy light. Lit from start of cycle to 3
minutes after closing.
This contact indicates the gate status. The relay is activated at the start of opening and turns off
only when closing is complete.
Only available if a two-channel radiocard is inserted
in the pre-installed connector
This output has the function of indicator light (with different flashes to indicate door status).
Door closed= off; in opening = slow flash; in closing= rapid flash; in pause = 2 flashes with pause;
door blocked with stop button = steady light.
II° Receiver
channel
Warning light
Dry contact
Courtesy light
contact
Output US1
(multipurpose)
mode). Clean
contact
OFF
ON
There is no slowdown in the last part of travel.
With the slowdown function connected, the motor halves its speedtowards
Slowdown
Select the options required and perform a reset (part. 7, fig. L) to render the changes operational.
41
Содержание ACE401
Страница 2: ...1 Fig A 1 7 6 5 14 12 11 13 10 9 4 3 2 8 15 I F E GB D NL ...
Страница 3: ...2 190 153 177 305 165 140 276 206 60 Fig B I F E GB D NL ...
Страница 4: ...Fig C dx dx sx sx Fig D 90 309 Fig E 40 80 40 3 I F E GB D NL ...
Страница 5: ...Fig F Fig H Fig G 5 10mm 4 I F E GB D NL ...
Страница 66: ...NOTE ...
Страница 67: ......