Operating Manual
Telco Multimeter
KE2500
KURTH ELECTRONIC www.kurthelectronic.de [email protected]
7
Connections and test leads
Test leads
To connect the measured wire pair shielded CAT III test leads are used with 4 mm
diameter and with the following color code:
n
Wire A
red
n
Wire B
green
n
Ground GND
black
The connection of the test leads
appended to the selected mode.
Side connections
n
USB 1-Port for data transfer
n
SD Card
Examination of the test leads
Functional test
1. Run before each use of the test device , a visual inspection of the test leads , probes and
Alligator clips are in good condition and undamaged and not cracked Insulation through.
2. Check the consistency of the test cable through solid short-circuit the test leads and reading the
resistor directly on the screen (the resistance should be less than 1.0) .
Terminals of the test cable
The test cables are connected as shown in Figure above. This figure shows the on top lying tester
sockets for the test cable.
Standard test cable
The red, green and black test leads to be plugged into the appropriate sockets on the top of the test
device , which the names + ( B green ), - ( A red) and earth ( E black ) bear (see illustration) The test probe
and alligator clips for connection to the circuit under test are also included.
A
B
E
-
+
USB 1
SD