background image

Revision A 

 

T-48 90 008 026 

 

2-13

During any test in the manual mode of operation, the operator may chose to repeat a particular test by 
toggling the 

STORE/REPEAT

 switch. The current test displayed will commence again. The operator may 

continue doing this as long as the Test Set remains “ON”. Turning the Test Set “OFF” and then “ON” will 
require the operator to go through all previous tests again to reach the desired test they want to repeat. By 
leaving the switch in 

REPEAT

, the test set will continue testing until toggled back to

 STORE. 

Always 

return the 

REPEAT

 switch to 

STORE

 when testing is completed. If left in the 

REPEAT

 position, the Test 

Set cannot be turned 

OFF.

 

 
 
2.11.3   Mode S Automatic Sequence of  Transponder Tests 
 

Figure 2-6 lists the sequence of tests performed with a Mode S equipped transponder under test. Paragraph 
2.11.4; Mode S Manual Sequence of Transponder Tests, describes in detail, each test performed. When the 

INTERROGATE

 button is depressed, the sequence will continue as long as normal results are received 

for each test. If an abnormal result occurs, the sequence will stop at that test and a “FAIL” message will be 
displayed. To override after a “FAIL” message, depress the 

INTERROGATE

 button to continue testing 

with the failure. 
 
                                                          First display shown once the T-48 has determined a Mode S equipped  
                                                          transponder is being received. 
                                                   
 
When selecting the Automatic sequence of tests, the results of the tests will not be displayed until the final 
test is completed. At that point, the POWER, RCVR & FREQ display will be shown and testing will end 
until the 

INTERROGATE

 or 

TEST

 buttons are depressed again to initialize another series of tests.  

 

 

  

 

 

NOTE

 

 
 

 

 

                                                          

The final display of Mode S Transponder tests alternates between two 

                    

 (2)  pages.  The  first  page  indicates  the  4096  octal  code,  the  decoded  

                       

aircraft address, aircraft altitude and power, sensitivity, and frequency 

                     

measurements. 

 

 

The second page displays the aircraft address in both Hexadecimal and  

                   

Octal, power measured in watts and the decoded Flight Identity. 

 
In the Automatic sequence of tests, “MAX TRUE AIRSPEED” and “VERTICAL STATUS BIT” tests are 
omitted. In addition, the operator will be unable to verify the UUT “IDENT” function. Pulse Width, Pulse 
Spacing and Data Pulse measurements are performed during the Automatic Sequence of tests. Utilize the 
Manual sequence of tests to verify a transponders “

IDENT

” function. 

 
 
 
 
 
 
 
 
 
 

MODE S XPDR COM/AB 
INTERROGATE TO TEST  

H:YYYYYY O:XXXXXXX 
250W  FID:DLXXXXXX 

4457 NXXXXX 10,000’ 
54dB-75dB 1090.0MHz 

Typically

, for U.S. civilian aircraft having MODE S addresses assigned, the number of 

the aircraft will be displayed. For non- U.S. and military aircraft, the MODE S address 
will appear as a Hexadecimal proceeded by the letter “N”. If a Hexadecimal address is 
displayed for a U.S. civil aircraft, this may indicate an incorrectly wired transponder. In 
the manual mode of MODE S tests, all addresses will be displayed in Hexadecimal.

Содержание T-48

Страница 1: ...5 230 VAC 50 400HZ CAGE CODE 92606 USA MOD 1 2 3 4 5 6 TEST INTERROGATE ACCESSORIES REPEAT OFF STORE ANTENNA LIGHTS OFF Transponder Test Set Operating and Maintenance Manual P N 90000026 REVISION Tel...

Страница 2: ...ible by including the page figure table number and send the information to Tel Instrument Electronics Corp Attention Technical Publications We will make every effort to resolve the issue in a timely a...

Страница 3: ...Revision A T 48 90 008 026 i T 48 MOD 3 TABLE OF CHANGES Date REV ECO Page Description 7 26 2002 A Initial Release...

Страница 4: ...Regulatory Responsibilities 1 2 1 4 Warranty 1 2 1 5 Safety Considerations 1 3 Section B Equipment Description 1 6 Specifications 1 4 1 7 Abbreviations Acronyms and Glossary of Terms 1 5 II Preparatio...

Страница 5: ...Automatic Sequence of Transponder Tests 2 11 2 11 2 Mode 3A C Manual Sequence of Transponder Tests 2 12 2 11 3 Mode S Automatic Sequence of Transponder Tests 2 13 2 11 4 Mode S Manual Sequence of Tes...

Страница 6: ...eceiver Local Oscillator Test 4 6 4 3 5 Omni Directional Antenna Transponder Test 4 6 4 3 6 TAP 135 Antenna Coupler Test 4 7 4 3 7 TAP 141 Direct Connect Antenna 4 8 Section C Annual Calibration and A...

Страница 7: ...nge to Digital 6 10 Cable Assembly Digital Range to RF 6 11 Cable Assembly LCD to Digital 6 12 Cable Assembly RF ANT Front Panel 6 13 TAP 135 Sub Assembly 6 14 TAP 141 Direct Connect Coupler Assembly...

Страница 8: ...Panel Interconnect Diagram Schematic 5 4 5 4 RF PCB Assembly 5 Pages Total Schematic 5 5 5 5 Digital PCB Assembly 4 Pages Total Schematic 5 10 5 6 Digital Range PCB Assembly Schematic 5 14 6 1 T 48 Ca...

Страница 9: ...Revision A T 48 90 008 026 vii List of Tables Table Title Page 2 1 T 48 MOD 3 Accessories 2 2 2 2 Controls Indicators and Connectors 2 3 2 3 Pulse Width and Spacing Criteria 2 21...

Страница 10: ...2 3 4 5 6 TEST INTERROGATE ACCESSORIES REPEAT OFF STORE ANTENNA LIGHTS OFF Figure 1 1 T 48 T 48A MOD 3 Transponder Ramp Test Set 1 2 Purpose and Function of the Equipment The T 48 T 48A MOD 3 Test Set...

Страница 11: ...n Tel s judgment that it is thus defective This warranty does not include batteries NiCad batteries have a 90 day warranty This warranty does not extend to any of Tel products which have been subject...

Страница 12: ...ies greatly improves the time it takes to complete the tests 4 Pay particular attention to NOTES and WARNINGS that may accompany some test procedures NOTE 5 Observe all standard safety procedures when...

Страница 13: ...ty 15 dBm Transponder Tests Receiver Sensitivity Range 65 to 88 dBm accuracy 3 dB Radiated Power 40 57 dBm 2 dB 10 500 watts Frequency 5 MHz 100KHz Reply Efficiency 0 to 99 1 Measurements made utilizi...

Страница 14: ...displayed when the transponder is determined to be a MODE S CW Continuous Wave D A Digital to Analog dB Decibel dBm Decibels above 1 milliwatt dc or DC Direct Current DME Distance Measuring Equipment...

Страница 15: ...ansmissions made by a MODE S transponder not in reply to an interrogation for the use of the collision avoidance system Surveillance Altitude An interrogation that causes only the addressed MODE S tra...

Страница 16: ...cation for shipping or extended storage Examine the unit for obvious signs of damage Check all displays switches and connectors before utilizing the Test Set If any damage is found DO NOT use the Test...

Страница 17: ...mbly AC Line Cord 75010025 1 3 TAP 135 Antenna Coupler 10 ft 89000145 1 4 Direct Connect Coupler TAP 141 89000147 OPTIONAL 5 TSP 1A Omni Antenna 40030011 1 6 Foam Insert Case 31000007 1 8 Operators Ma...

Страница 18: ...AC POWER Indicator Green LED indicates battery charging and AC power connected When the battery alone is being used the LED will not illuminate 5 VOLTAGE CHANGE FUSE CARTRIDGE Contains 2 250V amp remo...

Страница 19: ...AC 0 125 FTT T 48 MODE S ATCRBS TRANSPONDER RAMP TEST SET TEL INSTRUMENT ELEC CORP TYPE WATTS PART NO SERIAL NO INPUT 115 230 VAC 50 400HZ CAGE CODE 92606 USA MOD 1 2 3 4 5 6 TEST INTERROGATE ACCESSOR...

Страница 20: ...continue testing By observing a duty cycle of 50 the Test Set batteries will begin regaining their charge while testing is in progress It is strongly recommended that the batteries are charged for a...

Страница 21: ...the T 48 Test Set This is useful to determine and troubleshoot problems by separating the aircraft antennas and cables from the rest of the system The TAP 141 also provides the means to accurately me...

Страница 22: ...nsponder equipped ensure the correct antenna and transponder is selected 6 If unfavorable results occur when utilizing the Omni Antenna move closer to the transponder antenna and re test Aircraft exte...

Страница 23: ...wer frequency sensitivity and diversity measurements 2 The TAP 141 supplies an attenuated path protecting the Test Set from the high RF power associated with transponders 1 Ensure power to the transpo...

Страница 24: ...1 Transponder Test Sequence The T 48 is capable of testing ATCRBS Mode A Mode C and Mode S transponders The operator may select an Automatic sequence of tests ending in the Power Receiver Sensitivity...

Страница 25: ...EST MODE S SURV SHORT TEST MODE S COMM IDENTITY TEST UNDESIRED REPLIES TEST MODE S COMM ALTITUDE TEST SQUITTER TEST DIVERISTY TEST MAX TRUE AIRSPEED TEST VERTICAL STATUS BIT TEST POWER RCVR FREQ TEST...

Страница 26: ...he operator is alerted to continued and potential failures if testing is resumed Once the sequence is stopped due to a failure the operator may override and continue testing by depressing the INTERROG...

Страница 27: ...RE REPEAT switch on the T 48 The MODE 3A test will commence and the display will indicate IDENT verifying the SPI pulse was received IDENT signal received The TEST switch must then be pushed once more...

Страница 28: ...selecting the Automatic sequence of tests the results of the tests will not be displayed until the final test is completed At that point the POWER RCVR FREQ display will be shown and testing will end...

Страница 29: ...nless a failure was detected Mode 3A test complete Display indicates the transponders 4096 Octal code 1234 and receiver efficiency 100 as a percentage To test the transponder IDENT function press the...

Страница 30: ...MODE S transponder will not reply to an ATCRBS Only All Call A PASS displayed indicates that the Mode S transponder did not reply TEST button pressed to advance to next test MODE 3C ONLY test initial...

Страница 31: ...Hexadecimal aircraft altitude and flight status is displayed TEST button pressed to advance to next test MODE S COMM A Identity test initialized The Test Set transmits a COMM A B ABCD transmission ut...

Страница 32: ...Test Set will transmit no interrogations but receives and processes DF 11 and extended DF 17 replies After detection of the replies is received two alternating pages will be shown displaying the time...

Страница 33: ...pressed to advance to next test The VERTICAL STATUS BIT test is not performed during the auto sequence of Mode S tests Test Set receives the Vertical Status as part of the UF 0 format A display of ONE...

Страница 34: ...progressing The final test in the manual sequence will end with an alternating display of transponder RF power output 54dBm receiver sensitivity 75dBm and transponder frequency 1090 0 MHz The second...

Страница 35: ...g between F1 and F2 and Pulse width of F2 DP Signifies a Data Pulse Failure F1 Pulse Width F1 F2 Spacing F2 Pulse Width A FAIL signifies a F1 F2 Width failure or a Framing Pulse Spacing Failure F1 out...

Страница 36: ...Set also performs Framing Pulse Width and Data Pulse Tests With 1234 entered the T 48 will measure Framing Pulses their width and their spacing The Test Set will also measure each Data Pulse in their...

Отзывы: