![Tektronix WFM200BC Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/tektronix/wfm200bc/wfm200bc_instructions_1077553001.webp)
xx
General safety summary
Use the product only as speci
fi
ed. Review the following
safety precautions to avoid injury and prevent damage to this
product or any products connected to it. Carefully read all
instructions. Retain these instructions for future reference.
Comply with local and national safety codes.
For correct and safe operation of the product, it is essential
that you follow generally accepted safety procedures in
addition to the safety precautions speci
fi
ed in this manual.
The product is designed to be used by trained personnel only.
This product is not intended for detection of hazardous
voltages.
To avoid
fi
re or personal injury
Use proper power cord.
Use only the power cord speci
fi
ed
for this product and certi
fi
ed for the country of use.
Ground the product.
This product is indirectly grounded
through the grounding conductor of the mainframe power
cord. To avoid electric shock, the grounding conductor must
be connected to earth ground. Before making connections
to the input or output terminals of the product, make sure
that the product is properly grounded.
Do not disable the power cord grounding connection.
Power disconnect.
Remove the power cord of the external
AC adapter to disconnect mains power from the product.
Do not position the charger so that it is dif
fi
cult to operate
the power cord; it must remain accessible to the user at all
times to allow for quick disconnection if needed.
Use proper AC adapter.
Use only the AC adapter speci
fi
ed
for this product.
Use proper battery charger.
Use only the WFM200BC
charger or a Tektronix WFM2200, WFM2200A, or
WFM2300 waveform monitor to charge the WFM200BA
Lithium-Ion battery pack.
Do not operate without covers.
Do not operate this product
with covers or panels removed.
Do not operate with suspected failures.
If you suspect there
is damage to this product, have it inspected by quali
fi
ed
service personnel.
Disable the product if it is damaged. Do not use the product
if it is damaged or operates incorrectly. If in doubt about
safety of the product, turn it off and disconnect the power
cord. Clearly mark the product to prevent its further
operation.
Examine the exterior of the product before you use it. Look
for cracks or missing pieces.
Avoid exposed circuitry.
Do not touch exposed connections
and components when power is present.
Recharge batteries properly.
Recharge batteries for the
recommended charge cycle only.
Do not operate in wet/damp conditions.
Be aware that
condensation may occur if a unit is moved from a cold to
a warm environment.
Keep product surfaces clean and dry.
Do not attempt to service this product.
There are no
serviceable components in the WFM200BC battery charger.
Safety terms in this manual
WARNING.
Warning statements identify conditions or
practices that could result in injury or loss of life.
CAUTION.
Caution statements identify conditions or
practices that could result in damage to this product or
other property.
Symbols and terms on the product
These terms may appear on the product:
DANGER indicates an injury hazard immediately
accessible as you read the marking.
WARNING indicates an injury hazard not immediately
accessible as you read the marking.
CAUTION indicates a hazard to property including
the product.
Compliance information
This section lists the EMC (electromagnetic compliance),
safety, and environmental standards with which the
WFM200BC charger complies. Compliance demonstrated
using high quality, shielded interface cables.
EMC compliance
EC Declaration of Conformity – EMC
Meets the intent of Directive 2004/108/EC for
Electromagnetic Compatibility. Compliance was
demonstrated to the following speci
fi
cations as listed in the
Of
fi
cial Journal of the European Communities:
EN 55103-1:2009 Environmental E2.
Product family
standard for audio, video, audio-visual. Industrial and light
commercial
1
Part 1 Emission
EN 55022:2006 Class B – Radiated and conducted
emissions
EN 55103-1:2009 Annex A – Radiated magnetic
fi
eld emissions
Part 2 Immunity
EN 55103-2:2009 Annex A – Radiated magnetic
fi
eld immunity
IEC 61000-4-11:2004 – Power line voltage dip and
interruption immunity
IEC 61000-4-2:2000 – Electrostatic discharge
immunity
IEC 61000-4-3:2007 – RF electromagnetic
fi
eld
immunity
IEC 61000-4-4:2004 – Electrical fast transient /
burst immunity
IEC 61000-4-5:2005 – Power line surge immunity
IEC 61000-4-6:2006 – RF conducted immunity
1
Average half-cycle r.m.s. Inrush current at initial switch on : 2.8 A. Average
half-cycle r.m.s. Inrush current after 5 second power interruption: 2.4 A.
EN 61000-3-2:2006.
AC power line harmonic emissions
EN 61000-3-3:1995.
Voltage changes,
fl
uctuations, and
fl
icker
WFM200BC
External Battery Charger
ZZZ
Instructions
x
*P075104202*