Basic Installation
Benchtop Mainframe Site
Considerations
The Benchtop Mainframe is designed to operate on a bench, on a cart, or
in a rackmount environment. If you need to stack more than two benchtop
mainframes, install the mainframes in a rack. Refer to the online help under
Standard and Optional Accessories for rackmount kit part numbers.
WARNING.
To avoid personal injury, never lift or move a benchtop mainframe
by yourself. The size and weight of the mainframe requires two people to lift or
move it.
Do not stack more than one benchtop mainframe on top of another benchtop
mainframe. Always use a rackmount kit to ensure that the mainframes are secure
and will not fall.
Support Hardware Site
Considerations
The TLA7PC1 Benchtop PC Controller, TL708EX Hub, and GbE switch units
can operate separately on your workbench, equipment rack, or cart, or you can
mount them to your benchtop mainframe using the brackets provided with the
benchtop mainframe.
Installing the Bracket Kit
If you are using your benchtop logic analyzer outside of a rackmount environment,
you can use the bracket kit to mount the PC controller, GbE switch, and TL708EX
Hub together with your benchtop mainframe. (See Figure 1 on page 3.) Use
the following procedure:
1.
Place the components you want to mount on top of the logic analyzer, putting
the heaviest units lowest in the stack.
2.
A left and right-side bracket is included in the kit, along with mounting
screws. Align one of the brackets to the frame of the logic analyzer so that
the bracket reaches all of the components, but minimize the extra bracket
height above the top unit.
3.
Fasten the bracket to the logic analyzer with one of the 8-32, P2 Pozidriv
screws preinstalled on the bracket.
4.
Repeat steps 2 and 3 for the bracket on the other side of the logic analyzer.
5.
If necessary, relocate the instrument brackets on the components you are
mounting. For example, the brackets on the TL708EX Hub come mounted to
the back of the unit, with installation instructions on the bottom of the unit.
6.
Using the 10-32, P2 Pozidriv screws preinstalled on the brackets, fasten the
components to the brackets.
2
TLA7000 Series Logic Analyzers Installation Manual
Содержание TLA7000 Series
Страница 1: ...TLA7000 Series Logic Analyzers Installation Manual www tektronix com 071 1747 03 ...
Страница 72: ...Basic Installation 54 TLA7000 Series Logic Analyzers Installation Manual ...
Страница 88: ...Merging Modules 70 TLA7000 Series Logic Analyzers Installation Manual ...
Страница 104: ...Restoring and Reinstalling Software 86 TLA7000 Series Logic Analyzers Installation Manual ...
Страница 118: ...Appendix D TLA7000 Network Installation Site Survey 100 TLA7000 Series Logic Analyzers Installation Manual ...